F. Install the new postfilter cartridge into the postfilter head on the right-hand
side of the bracket manifold. Install the membrane cartridge into the center of
the bracket manifold
G. Mix 1/3 cup clean water with one level teaspoon of Iron Out or sodium
metabisulfite. Add this solution to the sanitizer cartridge left from Step E.
A small, plastic household funnel or the dropper provided in Kinetico' s
sanitization kit may aid in adding solution to the cartridge. Be sure to
throughly wash the funnel before using for any other purpose. Add enough
clean water to this cartridge to fill it and install it to the prefilter head
H. Disconnect the tubing from the storage tank valve and put the tubing end
into a bucket or pan. Open the cold water supply valve and allow the product
water to discharge from the tubing into the bucket or pan for 15 to 20
minutes. This should adequately flush the sanitization solution through the