Troubleshooting

Fault
Cause
Fastener system
Foreign objects in
jammed
zipper mechanism
Excess friction
Chemical
Fastener system
protective suit
not closed
leaky
Suit material
damaged
Safety boots or
gloves faulty or
leaky joint
Valve disc or seat
dirty or faulty
Full face mask or
face cuff leaking
Chemical
Valve disc on suit
protective suit not
valve sticks
ventilated
Hook-and-loop
The hook-and-loop
strap becomes
strap is attached
detached
with adhesive.
Cleaning and
decontamination
can cause it to
become loose.
1
not part of the EU type approval test
Dräger CPS 7800
6
6.1
The specified intervals are recommendations from Dräger. If
required, deviating national guidelines must be observed.
For maintenance work on the full face mask, air supply unit and
compressed air breathing apparatus, see the relevant
operating instructions.
i
1
Remedy
Clean zip fastener,
remove foreign
objects
Lubricate zip
fastener with
grease stick
Close fastener
system completely
Repair with suit
repair kit. Check
Work to do
for leaks again.
Replace or seal.
Check for leaks
again.
Visual inspection of the chemical
protective suit
Clean or replace.
Check for leaks
Cleaning and disinfecting the
again.
chemical protective suit
Replace or seal.
Maintaining the fastener system
Check for leaks
Service the face cuff
again.
Clean or replace.
Check the seal on the chemical
Check for leaks
protective suit
again.
Check the seal on the suit valve
Reapply adhesive
to the hook-and-
1
loop strap. Check
for leaks again.
2
i

Maintenance

Maintenance table

NOTICE
i
Originally lead sealed chemical protective suits have to
be checked after five years, if they were stored in a
CPS storage and transportation bag. After this period
or when the seal is broken, chemical protective suits
must be serviced in accordance with specified
intervals.
Chemical protective suits with integrated full face mask
are not sealed as the full face mask is subject to other
maintenance intervals.
Applies to chemical protective suits that are stored without
carrying bag on vehicles.
With chemical protective suits that are stored in the relevant
carrying bag, the interval is extended to two years.
Optional during the incoming goods inspection of an originally
sealed chemical protective suit.
NOTICE
i
Dräger recommends keeping a record of all
maintenance work (see chap. 10 on page 39).
Troubleshooting
1
X
X
X
X
1
X
X
X
1
X
X
X
2
1
X
X
X
X
2
1
X
X
X
X
29