Function Of The Indicators - Dini Argeo NWL Série Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CALI.
U
MODE
SET

4.2 FUNCTION OF THE INDICATORS

INDICATOR
0   
NET
PCS
%
kg
lb
- Function of incrementing the active digit when setting a value for parameters or
other functions.
- If pressed at length it access to the calibration with no zero acquisition and no
capacity selection (see section 6.3).
- Pressed in weighing phase together with the ENTER key, it access to the setting of
the number of divisions and zero tracking (see section 6.1).
- Pressed at start-up, during self-checking, together with the ENTER key, it access to
the calibration with zero acquisition and capacity selection (see section 6.4).
- It executes the conversion between "kg" and "lb (see section 5.6).
- It allows the selection of the functioning mode: weighing, counting, percentile weight
(see section 5.5)
- Pressed at start-up, during self-checking together with the SET key it access to the
setting of the FILTER (see section 6.5).
- Secondary function to return to normal operation when the scale is in a parameter
setting mode.
- When in weighing mode, it allows to set the weight thresholds (see section 5.9).
- When in counting or percentile mode, it allows to execute a new reference or
matching operation (see section 5.7 and 5.8).
Indicates that the weight detected on the weighing system is near zero.
Indicates that the displayed weight is a net weight.
Indicates that the number of sampled pieces is being displayed (see section 5.7).
Indicates that the weight is displayed in percentile of the sample weight (see section
5.8).
Indicates the unit of measure in use (kilogram).
Indicates the unit of measure in use (pounds).