5.2

CONNECTING THE BATTERy

IMPORTANT: To avoid damage to the unit, never connect outputs together or in par-
!
allel!
Important!!! Before connecting a battery pack, make one last check that all the set para-
meters are correct! The battery may be damaged, explode or catch fire if the settings are
incorrect. To avoid a short-circuit with the banana plugs, always connect the charging leads
to the battery charger first and then to the battery. Follow the reverse procedure when dis-
connecting. Ensure correct polarity!
Equalizer connection:
The black wire of the voltage sensor lead from the battery must be connected to the charger
at the arrow marking. The arrow marking indicates the earth pole (negative). Ensure
correct polarity! See below!!
Note:
For safety reasons, when charging/discharging Lithium batteries, one should always
connect the battery voltage sensor lead to the charger!
This example only serves as a reference and is intended to demonstrate the connection
of the voltage sensor lead to the equalizer.
EQ-Adapter
robbe-PQ No.8213

6. AUTOMATIC MODE

When the "AUTO" button is pressed from the start display, the charger operates in auto-
© robbe Modellsport
Operating instructions
POWER PEAK® TRIPLE 360 W EQ-BID
robbe-JSTXH No.8214
EQ-Adapter
matic mode, whereupon, all the parameters are set
automatically. "AUTOMATIC" is only available for
NC / NiMH battery types.
9
Order No.
VOLTAGE SENSOR
+
+
+S1
+S2
+S3
EQ-Adapter
robbe-TP/FP No.8215
8562
-
-