Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3. Press the
and
signal range limitation function on/off.
Radio signal
Display
range limitation
function mode
C0
OFF
C1
ON
4. Press the OK button to accept the new
setting.
Factory settings
• Radio signal range limitation function
setting: C0 (OFF)
NOTE:
• For more information about how to register
the tool and Assembly Qualifier, see the
Assembly Qualifier instruction manual.

Buzzer setting

• You can select from three buzzer modes.
1. Set the tool to setting configuration mode.
(See page 10.)
. Press the A button once.
• The current setting value will be dis-
played.
3. Press the
and
desired value.
Display
b0
b1
Buzzer accompanying green indicator
b
Buzzer accompanying red indicator
4. Press the OK button to accept the new
setting.
NOTE:
• The tool ships with the buzzer mode set
to b0 by default.
LED light setting
• You can select from two LED light modes.
1. Set the tool to setting configuration mode.
(See page 10.)
. Press the B button once.
• The current setting value will be dis-
played.
buttons to set radio
Status
Tool is operational in the
absence of communica-
tions with the Assembly
Qualifier.
Tool is not operational
in the absence of com-
munications with the As-
sembly Qualifier.
buttons to set the
Function
No buzzer
3. Press the
desired LED mode.
Display
L1
L2
Linked to trigger switch operation
4. Press the OK button to accept the new
setting.
NOTE:
• The tool ships with the LED light mode
set to L1 by default.
Speed control function
• The speed (RPM) can be changed with the
amount of depression of the trigger.
1. Set the tool to setting configuration mode.
(See page 10.)
. Press the B button three times.
• The setting value will be displayed.
3. Press the
setting to ON or OFF.
Operation
P0
P1
4. Press the OK button to accept the new set-
ting.
Initializing all settings
Factory settings
• Speed adjustment function
→ GA1: 80 GA2: 75 GA3: 45
• Auto downshift function → 0
• Cross thread reduction function → R0
• Rundown error detecting function → 0
• Maintenance interval alarm function
→ 0
• Radio signal range limitation function
→ C0
• Buzzer setting → b0
• LED light setting → L1
• Speed control setting → P0
• This section explains how to revert all tool
settings to their default values at the time of
shipment from the factory.
• The error display will be turned off.
1. Set the tool to setting configuration mode.
(See page 10.)
- 13 -
and
buttons to set the
Function
Linked to LED light button
and
buttons to change the
Function
Speed control ON
Speed control OFF