Velleman WS3080 Mode D'emploi page 8

Masquer les pouces Voir aussi pour WS3080:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Indoor
unit mode
temperature
high alarm
low alarm
reset max
reset min
Outdoor
high alarm
humidity
low alarm
reset max
reset min
Outdoor
display mode
temperature
unit mode
high alarm
low alarm
reset max
reset min
UV index
Refer to §8.2 for more information.
high alarm
reset max
Wind
wind speed
speed unit
high alarm
direction alarm
reset max
02.02.2011
WS3080
select °C or °F
set the high alarm level
Press the ALARM ON/OFF button to enable/disable the alarm. When enabled,
the alarm icon
appears.
set the low alarm level
Press the ALARM ON/OFF button to enable/disable the alarm. When enabled,
the alarm icon
appears.
(both indoor temperature [8] and max icon (between [14] and [15]) are
flashing)
press and hold the ENTER button for ±3s to reset max value to current
measurement
(both indoor temperature [8] and min icon (between [14] and [15]) are
flashing)
press and hold the ENTER button for ±3s to reset min value to current
measurement
set the high alarm level
Press the ALARM ON/OFF button to enable/disable the alarm. When enabled,
the alarm icon
appears.
set the low alarm level
Press the ALARM ON/OFF button to enable/disable the alarm. When enabled,
the alarm icon
appears.
(both outdoor humidity [11] and max icon (between [14] and [15]) are
flashing)
press and hold the ENTER button for ±3s to reset max value to current
measurement
(both outdoor humidity [11] and min icon (between [14] and [15]) are
flashing)
press and hold the ENTER button for ±3s to reset min value to current
measurement
select whether to show outdoor temperature, wind chill or dew point on the
display [12]
select °C or °F
set the high alarm level
Press the ALARM ON/OFF button to enable/disable the alarm. When enabled,
the alarm icon
appears.
set the low alarm level
Press the ALARM ON/OFF button to enable/disable the alarm. When enabled,
the alarm icon
appears.
(both outdoor temperature [12] and max icon (between [14] and [15]) are
flashing)
press and hold the ENTER button for ±3s to reset max value to current
measurement
(both outdoor temperature [12] and min icon (between [14] and [15]) are
flashing)
press and hold the ENTER button for ±3s to reset min value to current
measurement
set the high alarm level
Press the ALARM ON/OFF button to enable/disable the alarm. When enabled,
the alarm icon
appears.
(both UV index [15] and max icon (between [14] and [15]) are flashing)
press and hold the ENTER button for ±3s to reset max value to current
measurement
select between average or gust wind speed (default = average)
select between km/h, mph, m/s, knots or bft (Beaufort) (default = mph)
set the high alarm level
Press the ALARM ON/OFF button to enable/disable the alarm. When enabled,
the alarm icon
appears.
set the wind direction alarm
Press the ALARM ON/OFF button to enable/disable the alarm. When enabled,
the alarm icon
appears.
(both wind speed [14] and max icon (between [14] and [15]) are flashing)
press and hold the ENTER button for ±3s to reset max value to current
measurement
8