Télécharger Imprimer la page

Bosch DWK65AJ0R Serie Manuel D'utilisation Et Notice D'installation page 13

Publicité

Les langues disponibles

Les langues disponibles

Sharp-edged components inside the appliance may
damage the connecting cable.
Do not kink or trap the connecting cable.
¡ The connection data can be found on the rating
plate. → Page 9
¡ The connecting cable is approx. 1.30 m long.
¡ This appliance complies with the EC interference
suppression regulations.
¡ The appliance corresponds to protection class 1.
You should therefore only use the appliance with a
protective earth connection.
¡ Do not connect the appliance to the power supply
during installation.
¡ Ensure that the protection against contact is guaran-
teed during installation.
12.7 Information on the installation situation
¡ Install this appliance on the kitchen wall.
¡ To install additional special accessory parts, ob-
serve the enclosed installation instructions.
¡ The appliance must be installed with no more than
one side directly next to a high-sided unit or a wall.
The distance between the appliance and wall or
high-sided unit must be at least 50 mm.
¡ The width of the extractor hood must correspond at
least with the width of the hob.
¡ To optimally detect the cooking vapours, install the
appliance in the middle of the hob.
12.8 Instructions for the exhaust air pipe
The appliance manufacturer does not provide any war-
ranty for faults attributable to the pipeline.
¡ Use a short, straight exhaust air pipe with as large a
pipe diameter as possible.
¡ Long, rough exhaust air pipes, many pipe bends or
small pipe diameters reduce the suction power and
increase the fan noise.
¡ Use an exhaust pipe that is made of non-combust-
ible material.
¡ To prevent condensate from returning, fit the ex-
haust pipe with a 1° gradient from the appliance.
Flat ducts
Use flat ducts with an inner cross-section that corres-
ponds to the diameter of the round pipes:
¡ Diameter of 150 mm corresponds to ap-
prox. 177 cm².
¡ Diameter of 120 mm corresponds to ap-
prox. 113 cm².
¡ Use sealing strips for different pipe diameters.
¡ Do not use any flat ducts with sharp bends.
Round pipes
Use round pipes with an inner diameter of 150 mm (re-
commended) or at least 120 mm.
12.9 Instructions for the air extraction mode
For air extraction mode, a one-way flap should be in-
stalled.
Notes
¡ If a one-way flap is not included with the appliance,
one can be ordered from a specialist retailer.
¡ If the exhaust air is conveyed through the external
wall, a telescopic duct should be used.
12.10 Information about circulating-air
mode
The appliance must only be operated when it is se-
curely installed and the pipework is connected.
12.11 Installation
Checking the wall
Check whether the wall is vertical and has sufficient
1.
load-bearing capacity.
The maximum weight of the appliance is 16 kg.
Drill the hole depth in accordance with the length of
2.
the screws.
The wall plugs must have a secure grip.
The enclosed screws and wall plugs are suitable for
solid brickwork. Suitable fasteners must be used for
other structures (e.g. plasterboard, porous concrete,
poroton bricks).
Preparing the wall
Ensure that there are no electrical wires, gas pipes
1.
or water pipes in the area where holes are to be
drilled.
Cover the hob to prevent damage.
2.
Mark a vertical centre line on the wall from the ceil-
3.
ing to the lower edge of the appliance.
Centre the angle brackets using the centre line.
4.
The centre of the angle brackets is marked with a
notch.
Align the angle brackets horizontally.
5.
Mark the holes for the angle brackets in the flue.
6.
Installation instructions en
13

Publicité

loading

Ce manuel est également adapté pour:

Dwk05g0 serieDwk095g60