9. TROUBLE SHOOTING
Depending on the symptoms that you notice, you can discover the probable cause and solve the problem.
Failure
The engine doesn't work
The fumigator pressure is low
The battery does not charge
If you have problems fuming with liquid:
Problem
No product comes out or it comes
out intermittently
Leakage of liquid
In any other case, take your machine to the service technician.
Cause
The battery is discharged
The battery is discharged
Battery is not properly connected to
the charger
The charger is not connected to the
network
Cause
The filter is clogged
The reservoir cap is incorrectly
mounted
The cover joint is defective
30/92
Action
Charge the battery
Charge the battery
Connect the battery correctly
Connect the charger
Action
Clean or replace as necessary
Fit the cover correctly
Change the joint