Télécharger Imprimer la page

Nilfisk FOOD Hybrid Foamatic MA2CM Mode D'emploi page 170

Publicité

6.6.1.
Supply of detergent
Satellite without User Pack system.
See drawing no 110003498
• Place the can with detergent in the can holder
• Check the suction filter for impurities.
• Put the suction hose into the can below product
level and avoid suction of air.
• After pre-rinsing, check again that the hose is suf-
ficiently below product level and avoid suction of
air during foam or spray operation.
• After use of and when changing product as well as
after use of the unit, remove the hose from the can
and rinse the product inlet line and injector with
clean water.
Satellite with User Pack system
See drawing no 110003485.
• Place the specially designed User Pack in the
automatic holder.
• If changing to a different product when ending the
cleaning process, rinse the product inlet line with
clean water as follows:
Replace the User Pack containing product by one
with clean water; place the foam nozzle and open the
spray gun/outlet valve. The product inlet line is now
rinsed with clean water before use of another product.
6.7. Hose Connection
• The special hose fitted with spray gun/outlet valve
is connected to the outlet quick coupling of the unit
(layout drawing).
• Maximum hose length: 30 m.
• It is recommended only to use Nilfisk FOOD
hoses, which have been tested for resistance.
>20 sec.
7. System preparation
7.1. Start up
In order to ensure a problem-free start up of a new
system the pipe system and pump must be flushed
and bled.
Bleeding the pipe system
110003498
1. Turn on the water supply to rinse and bleed the
entire system. If satellites are installed open the
tap furthest away until no air or dirt comes out.
Then rinse and bleed the next tap and continue
until the tap closest to you has been rinsed and
bled.
7.1.1.
Start
1. Make sure that the water and air supply to the
unit is open. For air see layout drawing. In case
of central chemical supply this must be activated
too.
2. Select requested function. Use the unit according
to the "User guide".
7.1.2.
Stop
1. Press"
2. Close the water supply (see drawing 110005285).
3. Close the air supply (see drawing 110005288).
4. Deactivate chemical supply by pulling up the suc-
tion hose or removing the User Pack.
7.1.3.
Adjustment of air
Remove the cover from the unit.
Adjust the air pressure on the reduction valve until an
appropriate foam quality is reached.
110005307
" to stop program if running.
Due to the following it is very important
to close water, air and chemical suplly
when the unit is not in use.
• If the air supply is open when the unit
is not in use - air might seep into the
water pipe - which means that the
system has to be bled again.
171

Publicité

loading