Télécharger Imprimer la page

NARDI COMPRESSORI ATLANTIC P100-G100 Manuel D'utilisation Et D'entretien page 9

Publicité

Les langues disponibles

Les langues disponibles

IMPORTANT:
PERIODIC SERVICING SHEET:
AFTER 25 HOURS OF WORK
Compressor oil level (ideal MAX)
Check seal of O-rings (filters and cartridge)
Check filling valve seal
Check seal of cooling pipes
Check manometer (with the compressor depressurized)
Carbon/sieve filter cartridge (see illustration)
EVERY 50 HOURS OF WORK
Replace compressor oil (350 ml)
Cleaning or replacement of intake filter cartridge
Inspection and cleaning of breathable air filter
EVERY 100 HOURS OF WORK
Clean valve seats
Replace intake filter cartridge
Check effectiveness of safety valve
EVERY 250 HOURS OF WORK OR ANNUALLY
Check pulley belts
EVERY 500 HOURS OF WORK
Service KIT ATLANTIC - 500 hours
ANNUALLY OR IF NECESSARY
Check the air quality with an aero-test
ATLANTIC 100 - Rev.00/19
ATLANTIC P100-G100
All maintenance operations must be conducted with the machine switched off and with the
electrical power supply disconnected
DATE
DATE
DATE
DATE
Contact a Nardi Compressori technician
Contact a Nardi Compressori technician
Cod. AT200-005
OPERATOR'S SIGNATURE
OPERATOR'S SIGNATURE
OPERATOR'S SIGNATURE
OPERATOR'S SIGNATURE
DATE
OPERATOR'S SIGNATURE
DATE
OPERATOR'S SIGNATURE
P a g .