DEVICE EXAMPLE WITH FINGERPRINT READER MODULE
Front
1
6
2
7
3
8
4
9
5
10
Inside
1
2
3
4
5
6
7
Some door stations of the D21x series have an optional additional Accessibility Module including status display
with three pictograms [calling, speaking, door opening], door opening acoustics and hearing loop. The module
complies with DIN 18040 (Construction of accessible buildings) when installed properly. The power supply for
the hearing loop must be provided by a separate power supply unit (15 - 48 VDC, 1 A) due to the high power
consumption.
VIDEOS
Need help with the installation? Be sure to
watch our installation videos which can be found
on http://www.doorbird.com/support
Each individual step of the installation is clearly
documented in the videos.
INSTALLATION
All the steps below should be carried out carefully
by a competent adult, taking into consideration any
applicable safety regulations. Please contact us
directly or seek the advice of a competent specialist.
Please ensure that all wires used for the installation
are undamaged along their entire length and
approved for this type of use.
Network speed and network components
Please ensure that the upload speed of your Internet
connection is at least 0.5 Mbps. You can also carry out
a speed test at any time via the DoorBird App. The
user experience is only as good as your network speed,
network stability and quality of your network com-
ponents, such as your Internet Router and WiFi access
points or WiFi repeaters. Please also make sure that
1) HDTV Video
2) Light Sensor
For night vision mode
3) Security screws
4) Motion Sensor
1) Main Electrical Unit
2) Yellow cable for
call button
Connected to
the illuminated call
button with
nameplate
5) Illuminated
call button with
nameplate
The illumination is
also acting as
Diagnostic LED(s).
6) Night Vision LEDs
3) Red cable for
Module Port 1
Connected to the
fingerprint reader
module
4) Green cable for
Module Port 2
(unused)
your network components are no older than two years,
have been manufactured by a well-known manufactu-
rer, and have the latest firmware installed.
Should these requirements not be fulfilled, it may
occur, for example that the performance of audio and
video is poor or push notifications are delayed or do
not arrive on your smartphone or tablet at all.
Requirements:
High-speed Internet (via landline): DSL, cable or
optical fibre
Network: Ethernet, with DHCP
7) Microphone
8) Loudspeaker
9) RFID Reader
10) Fingerprint Reader
5) Screw connection
terminal
6) LAN/PoE jack