EXT, EXT
Door opener button, max. 0 V DC / AC, 0 Ampere. These ports can be used to connect e.g.
a door opener button inside the home. It will trigger the first bi-stable latching relay of the
EXT
device (REL1, REL1).
EXT
NOT I CE
15 VDC -
15 V DC Power supply input, negative pole (-). Please connect the black wire of the DoorBird
power supply unit (mains adaptor) here, if you do not power the device using PoE.
NOT I CE
15 VDC +
15 V DC Power supply input, positive pole (+). Please connect the red wire of the DoorBird
power supply unit (mains adaptor) here, if you do not power the device using PoE.
NOT I CE
Only related for devices with call button(s):
4 PIN (SWITCH)
Use the yellow cable to connect the button to the IP Video Door Station.
Please take care when connecting the cables and wires. Connecting the cables and wires the wrong
NOTIC E
way may damage the device. Wires without insolation material must not protrude out of the green
screw connection terminal, it may lead to electrical short and damage the device.
The yellow, green, and red cables that lead out from the side of the Main Electrical Unit must only be
NOTIC E
used to connect components certified by Bird Home Automation.
8
ASSEMBLING THE FRONT PANEL
Assemble the front panel of the device to the
mounting housing (backbox) of the device.
1.) Pull the front
2.) Push the
panel into the
front panel
mounting
up.
housing
(backbox)
Please make sure to add no voltage on these ports. Extra voltage may destroy
the device immediately.
Do not power the device simultaneously via the power supply from the power
supply unit (mains adaptor) and the power supply via PoE.
Do not power the device simultaneously via the power supply from the power
supply unit (mains adaptor) and the power supply via PoE.
3.) Insert the
security
screws.
9
ACTIVATING THE DEVICE
Switch on the power leading to the assembly location
again. If you use PoE, make sure to switch on power
of the PoE-Switch or PoE-Injector you have connected
the device to.
Do not power the device simultaneously via
NOTI CE
the power supply from the power supply
unit (mains adaptor) and the power supply
via PoE.
You can see if the device is powered by checking the
Diagnostic-LED, which lights up after about 30 to 60
seconds after the power is connected. The device is
ready for operation (booting up process, any software
updates, etc.) once it has emitted a short diagnosis
sound from the integrated loudspeaker. This may last
for up to 5 minutes. If the Diagnostic LED does not
light up, please check the power supply. Please
also check whether you have used a wall-plug power
supply and not PoE and whether you have connected
the positive pole and negative pole to the device
correctly.
11