Malfunction and remedy
Malfunction
The appliance is plugged in but
compressor and evaporator fail
to function
Appliance runs but no
condensation forms on
evaporator
Possible Cause
a) No current
b) Hygrostat incorrectly set
c) Technical fault in refrigeration
system
a) Operating temperature range
not reached or exceeded
b) Operating air humidity range
not reached
c) Suction wall or blow-out wall
obstructed
d) Technical fault in refrigeration
system
Remedy
a) Check fuses and electrical
connections
b) Check hygrostat setting
c) Contact after-sales service
a) Use appliance in correct
temperature range conditions
or adjust room temperature
accordingly
b) Use appliance only at 50 %
humidity or above
c) Allow adequate clearance of
the appliance, clean or
change the airfilter.
d) Contact after-sales service
15