2.5 Scope of application
To dehumidify the air in all rooms, cellars, living
or professional localities (exception: stables).
• As a security factor for stocking critical
goods like paper, cardboard carton, food-
stuff, coats etc.
• As rust protection for metals.
• To dry rooms and floor wet-cleaning, for
paint and paper hanger's works.
• To dehumidify humid rooms like for example
swimming pools.
• To dry damages due to humidity (flood
damage, inundation).
2.6 Preparations
The appliance has to be put in a stable position
and be levelled out so that the condensate can
drain off without problems.
• if possible, put the appliance in the middle
of the room in order to grant an optimal air
circulation
• you have to ensure that the air intake at the
front part can be done without problems,
same for the air outlet at the rear part of the
dehumidifier
• keep doors and windows closed
• the working range is between 5 and 32 °C
room temperature and at least 50 % relative
humidity.
2.7 De-Icer Control
Your dehumidifier is equiped with an automatic
de-icer control that guards against ice forming on
refrigeration coils in low temperature or low
humidity by switching-on the hot gas-defrosting.
The recommended humidity for living rooms is
about 50 % at 20 – 22 °C.
Important
Temperature, humidity degree and operating
conditions have influence on capacity of the
appliance. In winters with continuous frost,
when the weather is dry or in summertime, the
air-humidity may be very low (30 %). In these
cases the devices have only low or even no
efficiency. If no means of humidity measure-
ments are at hand, you can approximately
check the humidity with the hygrostat: the
appliance must not be under tension! Turn
slowly the knob of the hygrostat anticlockwise.
The flash above the knob shows approxi-
matively reached humidity-degree by a click
sound.
2.8 Setting into operation
1
2 3
7
8
1
Working hours-meter
2
Normal operation dehumdifying
3
Sensor malfunction
4
Defrosting
5
System OFF by excess temperature
6
System OFF by hygrostat
7
Power cord with plug
8
Main switch
9
Switch heater
10
Hygrostat connector
2.8.1 LED - Defrosting
The compressor turns, the fan is off. After
defrosting the device switches on again.
The device is equipped with an indication for
eventual malfunction of the sensing elements,
which control important values. In case of a faulty
sensing element, the device will turn off and the
LED „Sensor malfunction" will flash.