Télécharger Imprimer la page

Olsberg OSORNO L L Mode D'emploi Pour L'utilisateur page 32

Publicité

Les langues disponibles

Les langues disponibles

Installation instructions
EN
for the specialist company
2.6 Installation
Determine installation site
● See Chapter 2.5
> Installation site and installation requirements
● Remove transport locks!
2x
Fig. 2.5
Removing the transport locks
34
Aligning the stove with the height-adjustable feet
● Align the stove at the installation site using the height-adjustable
feet before connecting the stove!
● Turn out the adjustable feet by approx. 1 mm before installation!
!
Fig. 2.6
Aligning the stove with the height-adjustable feet
● Push the stove to the intended installation location and align the
stove so that the flue pipe fits into the pipe chuck (also note the
subchapter: „Aligning the stove with the height-adjustable feet")!
● The flue pipe connections must be sealed tight.
● In order to be able to clean the connecting pipe, bends with a
cleaning opening must be used.
● Take into account that the temperature of 85°C can be reached
on the movable walls in accordance with test regulation EN 13240
and that this can lead to colour changes on light-coloured wallpa-
per or similar combustible building materials.
● Minimum distances to the flue pipe of combustible materials
must be observed according to the „Technical regulations for sto-
ve and air heating construction":
- single-walled = 40 cm,
- double-walled = 20 cm spacing.
OSORNO L L/R
We reserve the right to make technical changes

Publicité

loading

Ce manuel est également adapté pour:

Osorno l r