Les langues disponibles

COOKTOP INSTALLATION WITH A
36" MONOGRAM DOWNDRAFT VENT,
MODEL ZVB36
The installation of the downdraft vent with
this cooktop requires careful consideration.
Both the cooktop and the vent must be installed
according to each specific installation instruction.
21-11/16"
cutout
depth
BASE CABINET REQUIREMENTS
The combined installation will fit in a standard
24" deep base cabinet. Use a 36" or wider base
cabinet.
– The vent housing, blower and ductwork will
occupy the base cabinet.
Installation Options
36-3/4"
3/8"
34" cooktop and
vent area cutout
7/16" cooktop overlap
(1-1/4" at center)
Front edge of countertop
COOKTOP REQUIREMENTS
The countertop must have a deep flat surface to
accommodate the cooktop and vent. Countertops
with a rolled front edge and backsplash will not
provide the flat surface area required.
• Review the illustration to determine the countertop
surface requirements.
– All cutout clearances for this installation must be
observed.
3/8"
1/8"
gap
23-5/16"
total flat
surface
required at
center
2-1/2" min. clearance
to cutout
POWER SUPPLY
If local codes permit, the vent and cooktop may
operate from the same 120V, 15 amp duplex outlet.
Locate the gas and electrical supply as shown on
page 8.