Télécharger Imprimer la page

Kohler K-1106 Guide D'installation page 16

Masquer les pouces Voir aussi pour K-1106:

Publicité

Les langues disponibles

Les langues disponibles

Troubleshooting Procedure (cont.)
Symptoms
2. Motor starts, not all jets
are functioning.
3. Whirlpool stops
automatically before 18
minutes.
4. Pump does not prime.
(Models with support
blocks only.)
5. Noisy operation.
6. Heater does not operate.
("H" models only)
1011092-2-E
All manuals and user guides at all-guides.com
Probable Causes
C. Air hose is pinched or kinked.
D. Part(s) of the push button
assembly is/are damaged.
E. Push button has grease in the
bleed area.
F.
Air hose is not properly installed
to the optional timer kit, or the
pump is in the "off" position.
G. Air hose is damaged.
H. Motor/pump does not work.
A. Jet is closed.
B. Jet not installed correctly.
C. Jets are blocked.
A. The GFCI or RCD trips.
B. Suction blocked.
C. Jets are blocked.
D. Motor overheated and protection
device activated.
A. Pump shimmed too high.
A. Pump banding straps have not
been cut. (Models with support
blocks only.)
B. Jet O-ring dislodged.
A. No power to heater.
B. Water temperature exceeds 104°F
(40°C).
C. Heater does not work.
16
Recommended Action
C. Adjust hose to clear the
pinched/kinked area. If the
tubing is pinched/kinked and
cannot be readjusted, or no
noticeable pinch/kink is
apparent, poke a small hole in
the tubing with a tack and try
the system again.
D. Replace the push button
assembly.
E. Disassemble the push button
assembly and wipe away any
excess grease. Reassemble the
button and retry the system.
F.
Refer to the timer kit installation
instructions to check the timer kit
installation. Contact the
installer/dealer.
G. Replace the air hose.
H. Rebuild or replace motor/pump.
A. Rotate jet trim ring
counterclockwise to open.
B. Reinstall jet; check for O-ring
damage.
C. Remove blockage.
A. Identify source of fault, and
correct.
B. Remove obstruction.
C. Remove blockage.
D. Check for blockage at motor
vents. Remove blockage and
allow motor to cool.
Check for suction blockage.
Remove blockage and allow
motor to cool.
Check for jet blockage. Remove
blockage and allow motor to
cool.
A. Lower pump support bracket.
A. Cut pump banding straps with
tin snips.
B. Remove jet, replace and lubricate
O-ring, and reinstall jet.
A. Reset the GFCI or RCD.
B. Allow water to cool and heater
will reengage.
C. Replace heater.
Kohler Co.

Publicité

loading