NOTE: Do not connect a VRLA (valve
regulated lead acid) battery. To charge
a VRLA battery, a special (constant-
voltage) battery charger is required.
NOTE: Do not connect any load to battery or
use engine starter motor while
charging. This causes high current to
fl ow through generator which will burn
out coil.
NOTE: Prior to charging battery, remove
positive and negative cables to battery.
1. Start generator.
2. Press DC circuit protector (X) in.
3. Connect red battery charger lead to positive
battery terminal. Connect black battery
charger lead to negative battery terminal. Do
not reverse these positions. Connect cord to
DC receptacle (Y).
Operating Range of DC Power Supply
(Charging 12V battery only):
This power source is designed to charge
batteries up to 40Ah that are half-discharged.
Do not charge batteries of a higher capacity
than 40Ah.
12V Battery:
Time required for recharging a battery varies
depending on discharge level of battery. When
specifi c gravity of battery reaches 1.26 to 1.28,
charging is complete. When charging, check
battery's specifi c gravity once an hour. Average
time for charging a half-discharged 40Ah
battery is approximately 5 hours. Be sure to
check battery fl uid level before charging.
DC Circuit Protector
NOTE: Reduce load of connected electric
device below specifi ed rated output of
generator if DC circuit protector (X)
turns off. If DC circuit protector (X)
turns off again, stop using device
immediately and contact a Kohler
portable dealer.
DC circuit protector (X) button will pop out,
stopping power to DC receptacle (Y) when
electric device being connected to generator is
operating at current above rated fl ows. To use
this equipment again, press DC circuit protector
(X) button.
Starter Battery
As starter battery (AI) is maintenance-free, just
check condition and tightness of connections
and its general cleanliness.
Generator and Retention Container
NOTE: Clean inside and outside of generator
regularly. Clean generator more
frequently if it is installed in a densely
wooded area or in a corrosive
atmosphere, or if it has been made
dirty by dust or organic material (rotting
leaves, moss, fecal matter, etc.).
10
All manuals and user guides at all-guides.com
NOTE: When cleaning exterior, a cleaning
1. Wash outside of generator using water with a
2. Rinse with clear fresh water to remove any
3. Open generator top cover (A) and engine
4. Check that there is no fl uid or debris in
5. Any fl uids present in retention container (F)
6. Close generator top cover (A) and engine
Before transporting generator, check that
bolts are correctly tightened, close fuel valve
and disconnect battery. Generator should be
transported in its normal operating position;
never lay it on its side. Ensure where generator
is to be stored or used is carefully prepared
beforehand.
We recommend that you use a Kohler portable
dealer for all maintenance, service, and
replacement parts for engine. To fi nd a Kohler
portable dealer visit KohlerPower.com or call
1-800-544-2444 (U.S. and Canada).
Long-term storage of your generator will require
some preventative procedures to guard against
deterioration.
NOTE: Do not connect with any electrical
If generator will be out of service for 2 months
or more follow procedure below.
1. Replace fuel fi lter (G).
2. Add STP® Diesel Fuel Injector Treatment to
3. Start engine, ensure there are no fuel leaks
4. While engine is still warm, change oil and
5. Clean precleaner (K).
6. Clean generator.
7. Cover generator with a protective cover to
KohlerPower.com
foam may be used and wiped off using
a soft, absorbent cloth. Stubborn stains
may be removed using a suitable
solvent (white spirit or equivalent) and
wiped off using a soft, absorbent cloth.
mild detergent added (e.g. car shampoo).
trace of cleaning product.
access door (E).
retention container (F). If necessary, pump
fl uid into a suitable container.
(rainwater, engine oil or fuel) must be
recycled or eliminated according to local
regulations in force.
access door (E).
Transporting Generator
Repairs/Service Parts
Storage
devices (unloaded operation).
fuel following directions on bottle.
and then stop engine.
replace oil fi lter (AE).
protect it against dust and store it in a clean
and dry place.