Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Models 27XL
Explosion-Proof LED Warning Light
25500044 Rev A2 0222
Limited Warranty: This product's limited warranty can be
found at www.fedsig.com/SSG-Warranty
SAFETY MESSAGES TO INSTALLERS AND USERS
This product should be installed and maintained by a
licensed electrician who is thoroughly familiar with the
National Electrical Code and will follow NEC guidelines
and local codes. Failure to follow all safety instructions
may result in property damage, serious injury, or death.
The selection of the mounting location for the device,
its controls, and the routing of the wiring is to be
accomplished under the direction of the facilities engineer
and the safety engineer. Listed below are some other
important safety instructions and precautions you should
follow:
Read and understand all instructions before
operating this system.
After installation, ensure that all set screws and
threaded joints are properly tightened.
Any maintenance to the light system must be done
with power turned off.
To be an effective warning device, this product
produces bright light that could be hazardous to your
eyesight. Do not stare directly at the light. Rapid
flashing could induce photosensitive epilepsy.
Never alter the unit in any manner. Safety in
hazardous locations may be endangered if additional
openings or alternations are made.
The nameplate, which may contain cautionary or
other information of importance to maintenance
personnel, should NOT be obscured in any way.
WARNING— EXPLOSION HAZARD: Disconnect the
fixture from the supply circuit before opening. Keep
tightly closed when in operation. Do not disconnect
while circuit is live. Substitution of components may
impair suitability for CIass I, Division 2. Do not install
in a hazardous location if the operating temperature
exceeds the atmosphere's ignition temperature.
OVERVIEW— Model 27XL is an explosion-proof visual
signal device for hazardous and marine locations, that
features an LED array with a flash rate of 60 flashes
per minute. Units are available in 24 Vac/Vdc and 120-
240 Vac 50/60 Hz.
Units may be configured as steady-on. Contact Technical
Support for details.
This equipment is suitable for use in Class I, Div. I, Groups
C and D; Class I, Div. 2, Groups A, B, C and D; Class II,
Div. 1, Groups E, F, and G; Class III, or non-hazardous
locations. For indoor and outdoor use; also Listed as a
marine visual signal appliance.
These devices are intended for permanent installation and
operation in accordance with Title 46, Code of Federal
Regulations, Parts 110-113, or Title 33, Code of Federal
Regulations, Part 183, Sub-part I, Section 183.410, and the
applicable requirements of the American Boat and Yacht
Council, Inc., and/or ANSI/NFPA 302, "Fire Protection
Standard for Pleasure and Commercial Motor Craft."
Installation
Unpacking the Device: After unpacking the device,
examine for damage and verify parts. The package comes
with one 27XL assembled unit without a mount. The
mount is sold separately. If a part is missing or damaged,
do not attempt to install. Contact Federal Signal Customer
Support at +1 708-534-4756 or iordersup@fedsig.com.
EXPLOSION HAZARD—This light fixture is not backward
compatible with older products. Do not use this light
fixture with the Series A versions of model CMXC,
CMXC-R, PMXC, PMXC-R, WMXC, or WMXC-R mounting
accessories. Failure to follow this warning may result in
personal injury or death.
Damaged glass domes can lead to explosions that could
result in serious injury or death. Replace damaged
domes.
The mount for the 27XL is required and sold separately.
There are three mounting options available: ceiling
(CMXC-SB), pendant (PMXC-SB) and wall (WMXC-SB).
Wiring must comply with Article 500 of the National
Electrical Code and the local authority having jurisdiction.
For marine applications, all wiring (including supply
wire) must be stranded wire and meet the USCG (CFR46)
Section (110-113).

Publicité

loading

Sommaire des Matières pour Federal Signal 27XL

  • Page 1 Substitution of components may impair suitability for CIass I, Division 2. Do not install The mount for the 27XL is required and sold separately. in a hazardous location if the operating temperature There are three mounting options available: ceiling exceeds the atmosphere’s ignition temperature.
  • Page 2 Technical Assistance: Contact our Technical Support source. Team at +1 708-587-3587 or signalsupport@fedsig.com. After the mount is installed and wired, the 27XL threads Repair Service: A return authorization is required. Contact onto the mount making electrical connection. Make your Authorized Distributor or Federal Signal Customer sure the o-ring seal is present on the mount and tighten Support.
  • Page 3 LED Emitter, Red K14700030A-R LED Emitter, White K14700030A-W Glass Dome Assembly K8436147A PC Board Assembly, 24 V K2005455A PC Board Assembly,120-240 V K2005416A Accessories Description Part Number Dome Guard DGXC-SB Ceiling Mount CMXC-SB Wall Mount WMXC-SB Pendant Mount PMXC-SB Federal Signal signaling.fedsig.com...
  • Page 4 2645 Federal Signal Drive, University Park, Illinois 60484 Additional translations available at signaling.fedsig.com Traducciones adicionales disponibles en signaling.fedsig.com Customer Support 1-800-344-4634+1-708-534-4756, iordersup@fedsig.com Technical Support 1-800-755-7621+1-708-587-3587, signalsupport@fedsig.com signaling.fedsig.com Federal Signal signaling.fedsig.com...
  • Page 5 Código Eléctrico GENERAL— El modelo 27XL es un dispositivo de señal Nacional (National Electrical Code, NEC) y que siga las visual a prueba de explosiones para ubicaciones marinas directrices de dicho código y los códigos locales.
  • Page 6 Reemplazar cúpulas dañados Después de instalar y cablear el soporte, el 27XL se Es necesario el soporte para el modelo 27XL y se vende enrosca en el soporte para hacer la conexión eléctrica. por separado. Hay tres opciones de montaje disponibles: Asegúrese de que el sello de la junta tórica esté...
  • Page 7 Servicio de reparación: se requiere una autorización de devolución. Comuníquese con su distribuidor autorizado Conjunto de placa de circuito K2005416A o con el servicio de Atención al Cliente de Federal Signal. impreso, 120-240 V Los productos defectuosos bajo garantía se repararán o Tabla 2 Accesorios reemplazarán a criterio de Federal Signal.
  • Page 8 2645 Federal Signal Drive, University Park, Illinois 60484 Additional translations available at signaling.fedsig.com Traducciones adicionales disponibles en signaling.fedsig.com Atención al cliente 1-800-344-4634+1-708-534-4756, iordersup@fedsig.com Soporte técnico 1-800-755-7621+1-708-587-3587, signalsupport@fedsig.com signaling.fedsig.com Federal Signal signaling.fedsig.com...
  • Page 9 • Ne modifiez jamais cet appareil de quelque façon Le paquet est livré avec une unité assemblée 27XL que ce soit. La sécurité dans les zones dangereuses sans support. Le support est vendu séparément. Si une peut être compromise si d’autres ouvertures...
  • Page 10 (CMXC-SB), montage suspendu (PMXC-SB) et montage mural (WMXC-SB). Le câblage doit être Une fois le support installé et câblé, le 27XL se visse sur conforme à l’Article 500 du Code national de l’électricité le support pour établir une connexion électrique. Assurez- et aux préconisations de l’autorité...
  • Page 11 WMXC-SB Pendaison de montage (pendentif) PMXC-SB Retours de produits : Les retours requièrent l’autorisation de Federal Signal. Contactez votre distributeur agréé pour obtenir plus d’informations concernant notre politique de retour ou pour demander le retour d’un produit. Pièces de remplacement Contactez l’usine pour la disponibilité...
  • Page 12 2645 Federal Signal Drive, University Park, Illinois 60484 Additional translations available at signaling.fedsig.com Traducciones adicionales disponibles en signaling.fedsig.com Assistance clientèle +1 800 344 4634 et +1 708 534 4756, iordersup@fedsig.com Assistance technique +1 800 755 7621 et +1 708 587 3587, signalsupport@fedsig.com signaling.fedsig.com...