APP software setting
Download software(User for lead-acid battery) http://www.epever.com/en/index.php/
Tecknical/download (Android APP for the Solar Charge Controller)
Download software(User for lithium battery) http://www.epever.com/en/index.php/Teck-
nical/download (Android APP for the Li-Battery Solar Charge Controller)
Setting the control voltage value
The following rules must be observed when modifying the parameter values in User for lead-
acid battery.
• Over Voltage Disconnect Voltage > Charging Limit Voltage ≥ Equalize Charging Voltage ≥
Boost Charging Voltage ≥ Float Charging Voltage > Boost Reconnect Charging Voltage.
• Over Voltage Disconnect Voltage > Over Voltage Reconnect Voltage
• Low Voltage Reconnect Voltage > Low Voltage Disconnect Voltage ≥ Discharging Limit
Voltage.
• Under Voltage Warning Reconnect Voltage > Under Voltage Warning Voltage ≥ Dischar-
ging Limit Voltage.
• Boost Reconnect Charging voltage > Low Voltage Reconnect Voltage.
The following rules must be observed when modifying the parameter values in User for
lithium battery.
• Over Voltage Disconnect Voltage>Over charging protection voltage(Protection Circuit
Modules(PCM))+0.2V※;
• Over Voltage Disconnect Voltage>Over Voltage Reconnect Voltage=Charging Limit Volta-
ge ≥ Equalize Charging Voltage=Boost Charging Voltage ≥ Float Charging Voltage>Boost
Reconnect Charging Voltage;
• Low Voltage Reconnect Voltage>Low Voltage Disconnect Voltage ≥ Discharging Limit
Voltage;
• Under Voltage Warning Reconnect Voltage>Under Voltage Warning Voltage≥ Discharging
Limit Voltage;
• Boost Reconnect Charging voltage> Low Voltage Reconnect Voltage;
• Low Voltage Disconnect Voltage ≥ Over discharging protection voltage (PCM)+0.2V※;
WARNING: The required accuracy of PCM shall be at least 0.2V. If the deviation is higher than
0.2V, the manufacturer will assume no liability for any system malfunction caused by this.
52
ENGLISH
ENGLISH
ENGLISH
ENGLISH
Local load mode
Operation:
Step1: Press the "ENTER" button and hold 5s under the load mode interface.
Step2: Press the "SELECT" button when the load mode interface is fl ashing.
Step3: Press the "ENTER" button to confi rm the load mode..
NOTE: Please refer to chapter 4.2 for the load working modes.
Load working mode
1**
Timer 1
100
Light ON/OFF
Load will be on for 1 hour
101
after sunset
Load will be on for 2 hours
102
after sunset
Load will be on for 3~13
103 ~ 113
hours after sunset
Load will be on for 14 hours
114
after sunset
Load will be on for 15 hours
115
after sunset
116
Test mode
Manual mode
117
(Default load ON)
CAUTION: Please set Light ON/OFF, Test mode and Manual mode via Timer1. Timer2 will
be disabled and display „2 n „.
2**
Timer 2
2 n
Disabled
Load will be on for 1 hour
201
before sunrise
Load will be on for 2 hours
202
before sunrise
Load will be on for 3④13
203 ~ 213
hours before sunrise
Load will be on for 14 hours
214
before sunrise
Load will be on for 15 hours
215
before sunrise
2 n
Disabled
2 n
Disabled