NOTE: All PV modules in a given array are assumed to be identical.
*Isc=short circuit current(amps) Voc=open circuit voltage.
Model
Max. PV input current
BSS0211
10A
BSS1184
20A
*These are the maximum wire sizes that will fit the controller terminals.
CAUTION: When the PV modules connect in series, the open circuit voltage of the PV array
must not exceed 92V at 25° C environment temperature.
Battery and Load Wire Size
The battery and load wire size must conform to the rated current, the reference size as
below:
Model
Rated
Rated dischar-
charge
ge current
current
BSS0211
10A
10A
BSS1184
20A
20A
CAUTION: For the battery, the recommended wire will be selected according to the condi-
tions that its terminals are not connected to any additional inverter.
MOUNTING
WARNING: Risk of explosion!
Never install the controller in a sealed enclose with flooded batteries! Do not install in a
confined area where battery gas can accumulate.
WARNING: Risk of electric shock!
When wiring the solar modules, the PV array can produce a high open circuit voltage, so
turn off the breaker before wiring and be careful when wiring.
CAUTION: The controller requires at least 150mm of clearance above and below for proper
air flow. Ventilation is highly recommended if mounted in an enclosure.
44
ENGLISH
ENGLISH
Max. PV wire size*
4 mm
2
/ 12AWG
6 mm
2
/ 10AWG
Battery wire size
Load wire
4 mm
2
/ 12AWG
4 mm
2
/ 12AWG
6 mm
/ 10AWG
6 mm
/ 10AWG
2
2
ENGLISH
ENGLISH
INSTALLATION PROCEDURE:
Figure 2-1 Mounting
Step 1: Determination of Installation Location and Heat-dissipation Space
Determination of installation location: The controller shall be installed in a place with suf-
ficient air flow through the radiators of the controller and a minimum clearance of 150 mm
from the upper and lower edges of the controller to ensure natural thermal convection.
Please see Figure 2-1: Mounting
CAUTION: If the controller is to be installed in an enclosed box, it is important to ensure
reliable heat dissipation through the box.
Figure 2-2 Schematic of wiring diagram
Step 2: Connect the system in the order of (1) battery -> (2) load -> (3) PV array in ac-
cordance with Figure 2-2,"Schematic Wiring Diagram" and disconnect the system in the
reverse order (3) (2) (1)