Break-in Procedure
Serious damage may result if the following
break-in instructions are not closely followed.
This procedure is required only once, before the air
compressor is put into service.
1. Set the pressure switch "AUTO/O" lever in the "O"
position for "Off".
2. Plug the power cord into the correct branch circuit
receptacle.
3. Do not attach hose to outlet. Leave the outlet open
to the atmosphere.
1. Before attaching air hose or accessories, make
sure the "AUTO/O" lever is set to "O" and the air
regulator is closed.
2. Attach hose and accessories.
TOO MUCH AIR PRESSURE CREATES A
HAZARDOUS RISK OF BURSTING. CARE-
FULLY FOLLOW STEPS 3 AND 5 BELOW EACH
TIME THE COMPRESSOR IS USED.
Compressed air from the outfit may contain
water condensation. Do not spray unfiltered air
at an item that could be damaged. Some air
operated tools or devices may require filtered air.
Read the instructions for the air tool or device.
3. Check the manufacturer's maximum pressure rating
for air tools and accessories. The regulator outlet
pressure must never exceed the maximum
pressure rating.
4. Turn the "AUTO/O" lever to "AUTO" and allow tank
pressure to build. Motor will stop when tank
pressure reaches "cut-out" pressure.
5. Open the regulator by turning it clockwise. Adjust
the regulator to the correct pressure setting. Your
compressor is ready for use.
6. Always operate the air compressor in well-
ventilated areas; free of gasoline or other solvent
vapors. Do not operate the compressor near the
spray area.
All manuals and user guides at all-guides.com
OPERATING PROCEDURES
9 — ENG
4. Turn the regulator clockwise, opening it fully, to
prevent air pressure build-up in the tank.
5. Move the "AUTO/O" lever to "AUTO". The com-
pressor will start.
6. RUN THE COMPRESSOR FOR 15 MINUTES.
Make sure the regulator is open and there is no
tank pressure build-up.
7. After 15 minutes, close the regulator by turning it
counterclockwise. The air tank will fill to cut-out
pressure and then the motor will stop.
WHEN YOU ARE FINISHED:
7. Set the "AUTO/O" lever to "O".
8. Turn the regulator counterclockwise and set the
outlet pressure to zero.
9. Remove the air tool or accessory.
10. Open the regulator and allow the air to slowly
bleed from the tank. Close the regulator when
tank pressure is approximately 20 psi.
11. Drain water from air tank.
WATER WILL CONDENSE IN THE AIR TANK. IF
NOT DRAINED, WATER WILL CORRODE AND
WEAKEN THE AIR TANK CAUSING A RISK OF
AIR TANK RUPTURE.
NOTE:
If drain cock valve is plugged, release all air
pressure. The valve can then be removed,
cleaned, then reinstalled.
12. After the water has been drained, close the drain
valve. The air compressor can now be stored.
D20415