Télécharger Imprimer la page

Vermont Castings WR247001 Instructions D'installation page 3

Publicité

Les langues disponibles

Les langues disponibles

installation
Contact your local buildng inspector prior to installation.
A permit may be required in your area.
1. Remove all parts from inside the stove body.
2. Select the proper location for the stove. These appli-
ances must not be installed any closer than the mini-
mum clearance to combustible materials. shown in
Brick pattern (on diagram sheet). The stove must be
installed on a noncombustible surface as shown in
Figure 1.
Figure 1
Clearance from Combustible Materials
Back Wall
B
8"
A
D
8"
8"
* 16" (406 mm) in the US ** 18" (457 mm) in Canada
clearance to combustible Materials
ST1005
CDW244
6" Flue Required
clearances
A
B
9/08
Single wall
10Z\x" 10Z\x" 10Z\x"
Connector
(267) (267) (267) (483) (292) (483) (1372)
Double wall
2Z\x"
5"
Connector
(84)
(127) (64) (267) (140) (254) (1372)
Unit must be placed on a noncombustible floor protection
equivalent to 3/8" millboard. Floor protector must have min.
R value of .893. Consult your local building authorities for fur-
ther information.
3. If noncombustible materials have been installed on the
walls, obtain the minimum clearances from either the
manufacturer of these materials or the local building
inspector's office.
4. Install the refractory bricks. (Fig. 2) (Refer also to Page
11) Be sure all bricks are in place.
5. Install the stovepipe INSIDE the flue collar on the top
of the stove between the stove and chimney.
6. dO NOt use a grate to elevate the fire.
failure to follow the minimum clearance requirements
and noncombustible surface requirements may result
in an unsafe installation.
30005125
All manuals and user guides at all-guides.com
Back Wall
C
E
*16"
**18"
C
F
C
D
E
F
19"
11Z\x"
19"
2Z\x"
10Z\x"
5Z\x"
10"
Figure 2
Brick Placement
Be sure to
install two (2) full
bricks (S16040)
in baffle
parts and tools Required for unpacking
F
Residential
Single wall connector pipe or listed double wall con-
nector pipe as required
3/8" (10 mm) #6 sheet metal screws to secure connec-
tor pipe
Electric drill with 1/8" (3 mm), 5/32 (4 mm) and 3/16"
(4.5 mm) drill bits
Screwdriver to secure sheet metal screws
Mobile Home and Outside air Option
In addition to tools required for residential installation you
will require:
G
1/4" carbide drill bit
54"
Hammer
54"
A saw capable of cutting a 4" diameter hole. Refer to
instruction sheet with the outside air kit
unpacking
Cut and remove strapping bands. Remove cardboard car-
ton, loose parts and packing.
Inspect stove for possible damage received during ship-
ping.
1. A clearance of 18" (457 mm) between the stovepipe
and combustible materials may be required. Check
with authorities having jurisdiction in your area.
2. All pipe sections must be connected with the male end
(crimped end) toward the stove.
3. Fasten the stove pipe to the flue collar by the use of
three (3) sheet metal screws. Do the same at each ad-
ditional joint to make the entire installation rigid.
4. Maintain the required diameter flue for the entire instal-
lation.
Windsor High Efficiency Wood Stove
Two (2) Full Bricks
ST1019
and assembly
Stove pipe
Baffle Assembly
3

Publicité

loading