Setup; Add One User; Adding User W/ Auto-Increment; Delete One User - GE ARITECH CS1700 Manuel D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12

Setup

1.
Enter [*] [5] and the User master code.
2.
Enter a 2-digit user number. To program a badge (add, delete,(de)activate), use the
user number 02. The LCD keypad displays the current code for this user. Stars [*]
represent blanks.
A. Add One User:
1.
The message "Enter New Code" appears. If the panel is programmed for 4-digit user
codes, press
6-digit user codes, press
user number is entered, LED1 on any enabled readers begins to flash.
2.
Badge the card designated for the entered user. If the user card is not already in the
system, it will be added and mapped to the entered user number and LED1 stops
flashing. If the card is already in the system, the reader triple beeps and LED1
continues flashing.
3.
After about 40 seconds, all the readers in the system are updated with the new user
card information.
B. Adding User w/ Auto-Increment:
1.
The message "Enter New Code" appears. If the panel is programmed for 4-digit user
codes, press
6-digit user codes, press
user number is entered, LED1 on any enabled readers will begin to flash.
2.
Badge the card designated for the entered user. If the user card is not already in the
system, it will be added and mapped to the entered user number and LED1 will
continue flashing indicating that the next user card can be badged for the next user
number. If the card is already in the system, the reader will triple beep and LED1 will
continue flashing; the user number is not incremented in this case.
3.
After about 40 seconds of no cards being badged, all the readers in the system will
be updated with the new user card information.
C. Delete One User:
1.
The message "Enter New Code" appears. If the panel is programmed for 4-digit user
codes, press
Proximity Reader Installation Manual
It is recommended that only one reader on the system be enabled to
add/delete user cards and that this reader be located near a keypad. This
reader will transfer information to all other readers in the system once
programming is finished.
Adding/deleting user cards from a reader causes the code for the user
number used to become invalid. It is necessary to re-enter user code 2 after
programming cards.
Only a master user can add or delete users.
g
followed by the 3-digit user number. If the panel is programmed for
g
followed by [0]-[0] and the 3-digit user number. If a valid
By default, user cards are added and activated. In order to add a user card
and deactivate it at the same time, scan and hold the card to be added until
two beeps are sounded at the reader.
i
followed by the 3-digit user number. If the panel is programmed for
i
followed by [0]-[0] and the 3-digit user number. If a valid
By default, user cards are added and activated. In order to add a user card
and deactivate it at the same time, scan and hold the card to be added until
two beeps are sounded at the reader.
h
followed by the 3-digit user number. If the panel is programmed for
7