Location 243 Programming the Zones (2 segments, ND)
Segment 1
Location 244 Programming the Various Reader Timers (4 segments, ND)
Segment 1
Segment 2
Segment 3
Location 245 Resetting the Reader Address (1 segment, ND)
If it is necessary to reset the address of the reader, enter a 0 in this location.
WARNING: This will cause the reader to cease functioning. If a card is badged with
the system in Program Mode, the reader will again find an available address and set itself,
beeping back to the user the address that was found as per the table on page 5. If the
system is not in Program Mode and a card is badged at a reader with a reset address,
then it will sound an error beep.
Operating power
Operating temperature
Quiescent state current draw
Operating state current draw
Open collector Output max current
Dimensions (W x H x D)
Proximity Reader Installation Manual
Door Shunt Zone. Program the zone that will be monitored for sounding the
Door Prop Alarm. Program a 0 (default) to disable this function. See
Location 244, Segment 3 for the length of time the zone is monitored before
sounding the alarm.
Scan Time. Enter the amount of time allowed for a double badge to be
detected and the amount of time required to hold a card to activate the
functions programmed in Location 0, Segments 2 and 3. This timer is timed
in 1/100 second increments from 0 to 2.55 seconds. (Default is 100 = 1
second).
Relay Active Time. Enter the amount of time the Relay Driver is energized
once activated. This timer is timed in 1 second increments from 0 to 255
seconds. (Default is 10 = 10 seconds).
Door Fault Warning Time. Enter the amount of time a monitored zone (see
Location 243, segment 2) must be faulted before sounding an alarm (local
buzzer). This timer is timed in 1 second increments from 0 to 255 seconds.
(Default is 30 = 10 seconds).
A 7. T
ECHNICAL
10.5-14 VDC supplied from CSx75 3-wire bus connection
-35°C to +66°C / Relative humidity max. 93%
40 mA
110 mA max.
25 mA
Approx 75 x 118 x 15 mm
S
PECIFICATIONS
11