SITRANS F M MAG 5100 W Electromagnetic flowmeter
Coil resistance
Manufacturer's design
and safety statement
We have checked the contents of this manual for agreement with the hardware
and software described. Since deviations cannot be precluded entirely, we cannot
guarantee full agreement. However, the data in this manual are reviewed regularly
and any necessary corrections included in subsequent editions. Suggestions for
improvement are always welcomed.
Technical data subject to change without prior notice.
Siemens Flow Instruments A/S
8
Nordborgvej 81
DK-6430 Nordborg
Order no. 7ME6520
DN
Resistance
25
104
40
92
50
119.4
65
127
80
126
100
125
125
126
150
116
200
109
250
104
300
108
350
100
400
100
450
100
500
100
600
98
700
98
750
800
98
900
98
1000
98
1100
1200
88
1400
1500
1600
1800
2000
All resistance values are at 20 °C.
The resistance changes proportionally 0.4% / °C.
1. Responsibility for the choice of lining and electrode materials with regard to their abrasion and
corrosion resistance lies with the purchaser; the effect of any change in process medium during
the operating life of the flowmeter should be taken into account. Incorrect selection of lining
and/or electrode materials could lead to a failure of the flowmeter.
2. Stresses and loading caused by earthquakes, traffic, high winds and fire damage not taken into
account during flowmeter design.
3. Do not install flowmeter such that it acts as a focus for pipeline stresses. External loadings not
taken into account during flowmeter design.
4. During operation do not exceed the pressure and/or temperature ratings indicated on the data
label or in the installation instructions.
5. It is recommended that all installations should include an appropriate safety valve and
adequate means for draining/venting.
6. Under the Pressure Equipment Directive this product is a pressure accessory, and not
approved for use as a safety accessory, as defined by the Pressure Equipment Directive.
7. Removal of the terminal box except by Siemens Flow Instruments or their approved agents will
invalidate the PED conformity of the product.
In accordance with the Pressure Equipment Directive (97/23/EC).
Coil resistance
Tolerance
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 6
± 6
± 6
± 6
± 6
± 6
± 6
± 6
± 6
± 6
The reproduction, transmission or use of this document or its contents is not permitted
without express written authority.
Offenders will be liable for damages. All rights, including rights created by patent grant or
registration of a utility model or design, are reserved.
Copyright © Siemens AG 07.2008 All Rights Reserved
Order no.: A5E00718677-04
Printed in: Denmark
Order no. 7ME6580
Resistance
Tolerance
104
± 2
92
± 2
92
± 2
100
± 2
94
± 2
92
± 2
92
± 2
94
± 2
90
± 2
92
± 2
100
± 2
112
± 2
100
± 4
108
± 4
122
± 4
115
± 4
128
± 4
133
128
± 4
131
± 4
131
± 4
126
130
± 4
130
124
133
133
147