Télécharger Imprimer la page

Wolf WF Serie Guide D'installation Et D'utilisation page 17

Publicité

Les langues disponibles

Les langues disponibles

WOLF WF FRYERS
w Do not use a metallic scoring pad or harsh cleaners.
Weekly or as required:
1. Drain the tank as described under DRAINING THE TANK.
2. Once the shortening has been drained, flush out scraps and sediment with a small
amount of warm shortening, using tank brush. Allow the tank to drain thoroughly.
3. Close the drain valve and fill tank water.
4. Add commercial boil-out solution. Follow instructions on the side of the package.
Solution level must be between the MIN and MAX levels on the fryer tank.
5. Set thermostat to the temperature recommended for the solution being used. Do not
exceed 200°F. Allow solution to simmer for about 15 to 20 minutes.
6. Drain the cleaning solution from the tank.
7. Close the drain valve and refill the tank with water. Add 1 cup (1/4 L) of vinegar to
neutralize alkaline left by the cleaner. Solution level must be between the MIN and
MAX level on the fryer tank.
8. Bring the solution to a simmer only, turn the thermostat off. Allow to stand for a few
minutes.
9. Drain the tank according to DRAINING THE TANK. Rinse thoroughly with clear, hot
water. All traces of cleaner must be removed. Dry the tank thoroughly.
10. Close the drain valve and add shortening. Follow the FILLING TANK WITH
SHORTENING procedure in this manual. The fryer is now ready for use.
When the fryer is cool, inspect annually. Check the flue and clear any obstructions.
WF Series Fryers
BOIL OUT PROCEDURE
Do not use chlorine or sulfate/sulfide cleaners.
Hot oil and hot parts can cause burns. Use care when operating,
cleaning, and servicing the fryer.
Spilling hot fryer compound can cause severe burns. Do not
move fryer without draining all frying compound from the tank.
FLUE VENT INSPECTION
MAINTENANCE
-17-
WF-53700 Rev. A (7-23)

Publicité

loading

Ce manuel est également adapté pour:

Wf300Wf400