EC5000 20 W – AI/BI – 48 V DC
Rated voltage
Voltage range
Rated current
Starting current
Switching threshold, signal input
"Rotational direction"
Maximum residual ripple of the
power supply
Maximum noise level
(mounted)
UL type rating
Ambient temperature in operation
Ambient temperature for
transport and storage
Altitude of installation site
All data applies for an ambient temperature of 20 °C (68 °F).
From 25 °C (77 °F), a derating factor must be taken into account.
Higher rated current at gear ratios of 78:1 and 108:1 (three-stage rather than two-stage gear)
1)
The actual current course is dependent on the circumstances of the application, such as conveyor weight, number of
2)
connected rollers, etc.
The value can vary depending on the installation condition, profile shapes and system resonance behaviour.
3)
Estimated derating: 5% from 1500 m (4920 ft), 10% from 2000 m (6560 ft).
4)
For use in Pollution Degree 3 and Overvoltage Category II environments only.
Version 2.5 (04/2020) UL
Translation of the original operating manual
Product information
48 V DC, protected extra-low voltage (PELV)
36 to 56 V DC
0.6 A/0.7 A
1)
1.5 A
2)
Safe "High": U > 7 V DC
Safe "Low": U < 4 V DC
3%
55 dB(A)
3)
Type rating 2
0 °C to +40 °C (32 °F to +104 °F)
-30 °C to +75 °C (-22 °F to +167 °F)
Max. 1000 m (3280 ft)
4)
27 of 116