1
SUB LEVEL
Presetting of the subwoofer volume in relation to the volume of the array columns. Basic setting 12 o'clock.
2
MAIN LEVEL
Presetting of the overall volume - the subwoofer is also controlled in accordance with the SUB LEVEL preset.
3

INDICATOR LEDS

ON: Lights up when power is switched on and mains cable is connected correctly.
SIGNAL: Lights up when the unit receives an audio signal.
LIMIT: Lights up when the loudspeaker is operated at its limit. Short-term blinking of the LED is not critical. If
the limiter LED lights up longer than a brief moment or permanently (= over-driving the system), reduce the
volume of the connected signal source. Non-compliance will lead to unpleasant and distorted sound and may
cause malfunction of the speaker system.
PROTECT: Lights up in case of unit overload/overheating. Amplifiers switch to mute automatically. The unit
will return to operation mode under normal conditions after a few minutes.