Process
Temperature
Standard model:
• –25 to +80 °C (–13 to +176 °F)
• CSA temperature code: T5
• maximum surface temperature
High temperature option:
• CE and General Purpose –25 to +600 °C (–13 to +1112 °F)
• FM/ATEX Hazardous
• CSA Class II Group E, F –25 to +195 °C (–13 to +383 °F), CSA
• CSA Class II Group G
• maximum surface temperature +250 ºC (+482 ºF) [ATEX relevant]
Pressure
• standard model
• high pressure options
The device construction allows over-pressure between –0.2 and 0.1 bar in
Note:
hazardous areas.
WARNINGS:
• This product is designated as a Pressure Accessory per Directive
97 / 23 / EC, and is not intended for use as a safety device.
• Materials of construction are chosen based on their chemical
compatibility (or inertness) for general purposes. For exposure to
specific environments, check with chemical compatibility charts
before installing.
Approvals
• FM/CSA Class II, Div. 1, Group E, F, G, Class III
• ATEX II 1/2 D (dust explosion)
• IECEx t IIIC Da/Db
• CE
• C-TICK
• FM/
CSA
C
USA
(see product nameplate for approval details)
• Food grade material (according to directive 1935/2004/EC)
Food grade material in contact with the process food (sealing and grease FDA.
conform). The option does not automatically implement a food conform design
(food conform gaps, suface and radiuses).
A5E34210883
SITRANS LPS200 – OPERATING INSTRUCTIONS
All manuals and user guides at all-guides.com
+120 ºC (+248 ºF) [ATEX relevant]
–25 to +250 °C (–13 to +482 °F)
temperature code: T2D
–25 to +160 °C (–13 to +320 °F), CSA
temperature code: T3B
max. 0.8 bar, gauge (11.6 psi, gauge)
max. 5 bar, gauge (72.5 psi, gauge)
max. 10 bar, gauge (145 psi, gauge)
General Purpose
Page EN-5

Publicité

loading