Fitting/Changing The Saw Blade - EINHELL TC-TS 315 U Instructions D'origine

Masquer les pouces Voir aussi pour TC-TS 315 U:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 40
in the same way as the guide rail for the par-
allel stop. The guide rail (41) should be in the
middle of the saw table (1).
Then tighten all the loose screw connections.
Important! Select a height for the guide rails
which ensures that:
they are parallel to the saw table,
the parallel stop (7) is not blocked by the saw
table (1) when pushed,
but that the gap between the guide rail and
parallel stop (7) is not too large.
6.3 Fitting/removing the table insert (Fig. 6)
To prevent increased likelihood of injury, the
table insert should be changed whenever it is
worn or damaged.
Take off the saw blade guard (2) (6.5).
Remove the countersunk head screw (17).
Take out the worn table insert (6).
To fit the replacement table insert, proceed in
reverse order.
6.4 Fitting/removing the splitter (Figs. 7-9)
Danger! Pull out the power plug.
Set the blade (4) to max. cutting depth, move
to 0° position and lock in place.
Remove the saw blade guard (see 6.5).
Take out the table insert (6) (see 6.3).
Slacken the fixing screw (19). Important! Sla-
cken the fastening screw (19) only as far as
necessary until the gap (14) is approx. 5 mm.
The fastening screw (19) does not have to be
removed to fit the splitter (5).
Insert the splitter (5) into the gap (14). Make
sure that the splitter has been fitted straight
and not wobbly.
The splitter (5) must be positioned in the cen-
ter along an imaginary line extending behind
the saw blade (4), so that it is not possible for
the material to get jammed.
The distance between the blade (4) and the
splitter (5) should be 3-8 mm.
Retighten the fastening screw (19) and fit the
table insert (6) and saw blade guard (2).
The splitter (5) must not be set to a depth of
more than 2 mm relative to the saw blade in
the vertical direction.
To dismantle, proceed in reverse order.
6.5 Fitting/removing the saw blade guard
(Figs. 1, 5)
Mount the saw blade guard (2) on the splitter
(5) so that the screw fits through the hole (18)
in the splitter.
Do not tighten the screw (15) and locking grip
Anl_TC_TS_315_U_SPK9-1.indb 32
Anl_TC_TS_315_U_SPK9-1.indb 32
GB
(48) too far – the saw blade guard must be
able to move freely.
To dismantle, proceed in reverse order.
Warning! The saw blade guard (2) must al-
ways be lowered over the workpiece before
you begin to cut.

6.6 Fitting/changing the saw blade

(Figs. 10/11)
Before changing the saw blade: Pull out the
power plug!
Wear work gloves to prevent injury when
changing the saw blade.
Set the blade (4) to max. cutting depth, move
to 0° position and lock in place.
Remove the saw blade guard (2), table insert
(6) and splitter (5) (see 6.5, 6.3, 6.4).
Place the face spanner (33) on the saw blade
flange (40) to apply counter-pressure and
undo the screw with the ring wrench (37).
Caution! Turn the screw in the direction of ro-
tation of the saw blade.
Take off the outer flange and pull the old saw
blade (4) off the inner flange.
Clean the blade flange thoroughly before fit-
ting the new blade.
Mount and fasten the new saw blade in rever-
se order.
Caution! Note the running direction. The cut-
ting angle of the teeth must point in running
direction, i.e. forwards (see the arrow on the
blade guard).
Refit and set the splitter (5), table insert (6)
and the saw blade guard (2) (see 6.4, 6.3,
6.5).
Check to make sure that all safety devices
are properly mounted and in good working
condition before you begin working with the
saw again.
Warning! Every time that you change the saw
blade, check that the saw blade guard (2)
opens and closes again in accordance with
requirements. Also check that the saw blade
(4) spins freely in the saw blade guard (2).
Warning! Every time that you change the saw
blade (4), check to see that it spins freely in
the table insert (6) in both perpendicular and
45° angle settings.
Warning! You should replace the table insert
(6) immediately whenever it is worn or dama-
ged (see 6.3).
Warning! The work to change and align the
saw blade (4) must be carried out correctly.
- 32 -
23.03.2020 09:16:57
23.03.2020 09:16:57

Publicité

Table des Matières
loading

Table des Matières