5. Technical data
Phoenix Inverter
Cont. power at 25 °C (1)
Cont. power at 25 °C / 40 °C
Peak power
Output AC voltage / frequency (adjustable)
Input voltage range
Low battery shut down (adjustable)
Low battery restart & alarm (adjustable)
Battery charged detect (adjustable)
Max. efficiency
Zero-load power
Default zero-load power in ECO mode
(default search interval: 2.5 s, adjustable)
ECO mode stop and start power setting
Protection (2)
Operating temperature range
Humidity (non-condensing)
Material & Colour
Battery-connection
Maximum cable cross-section
Standard AC outlets
Protection category
Weight
Dimensions (hxwxd, mm)
(hxwxd, inch)
Remote on-off
Automatic transfer switch
Safety
EMC
Automotive Directive
1) Nonlinear load, crest factor 3:1
2) Protection key:
a) output short circuit
b) overload
c) battery voltage too high
d) battery voltage too low
e) temperature too high
f) DC ripple too high
8
12 Volt
12/250
24 Volt
24/250
48 Volt
48/250
250 VA
200 / 175 W
400 W
87/88/88 %
4.2/5.2/7.9 W
0.8/1.3/2.5 W
ENCLOSURE
120 V: Nema5-15R, NEMA GFCI (2x Nema5-15R with GFCI)
2.4 kg/5.3 lbs
86x165x260
3.4x6.5x10.2
ACCESSORIES
STANDARDS
3) UL 458 only for inverters with GFCI output socket
12/375
24/375
48/375
375 VA
300 / 260 W
700 W
230 VAC or 120 VAC +/- 3 % 50 Hz or 60 Hz +/- 0.1 %
9.2 - 17 / 18.4 - 34.0 / 36.8 - 62.0 VDC
9.3 / 18.6 / 37.2 VDC
10.9 / 21.8 / 43.6 VDC
14.0 / 28.0 / 56.0 VDC
89/89/90 %
5.6/6.1/8.5 W
0.9/1.4/2.6 W
Adjustable
a – f
-40 to +60 °C (fan assisted cooling)
(derate 1.25 % per °C above 40 °C)
max 95 %
Steel chassis and plastic cover (blue Ral 5012)
Screw terminals
10 mm² / AWG8
230 V: Schuko (CEE 7/4), IEC-320 (male plug included)
UK (BS 1363), AU/NZ (AS/NZS 3112)
IP 21
3.0 kg/6.6 lbs
86x165x260
3.4x6.5x10.2
Yes
Filax or Multi
EN/IEC 60335-1 / EN/IEC 62109-1 / UL 458 (3)
EN 55014-1 / EN 55014-2
IEC 61000-6-1 / IEC 61000-6-3
ECE R10-4 EN 50498
12/500
12/800
24/500
24/800
48/500
48/800
500 VA
800 VA
400 / 350 W
650 / 560 W
900 W
1500 W
90/90/91 %
90/90/91 %
6/6.5/9 W
6.5/7/9.5 W
1 / 1.5 / 3 W
1 / 1.5 / 3 W
25/10/10 mm² /
AWG4/8/8
3.9 kg/8.5 lbs
5.5 kg/12 lbs
105x216x305
86x172x275
4.1x8.5x12.1
3.4x6.8x10.8
(12 V model:
105x230x325)

Publicité