5. Technical data, continued
Phoenix Inverter
Cont. power at 25 °C (1)
Cont. power at 25 °C / 40 °C
Peak power
Output AC voltage / frequency (adjustable)
Input voltage range
Low battery shut down (adjustable)
Low battery restart & alarm (adjustable)
Battery charged detect (adjustable)
Max. efficiency
Zero-load power
Default zero-load power in ECO mode
(default search interval: 2.5 s, adjustable)
ECO mode stop and start power setting
Protection (2)
Operating temperature range
Humidity (non-condensing)
Material & Colour
Battery-connection
Maximum cable cross-section
Standard AC outlets
Protection category
Weight
Dimensions (hxwxd, mm)
(hxwxd, inch)
Remote on-off
Automatic transfer switch
Safety
EMC
Automotive Directive
1) Nonlinear load, crest factor 3:1
2) Protection key:
a) output short circuit
b) overload
c) battery voltage too high
d) battery voltage too low
e) temperature too high
f) DC ripple too high
12 Volt
24 Volt
48 Volt
ENCLOSURE
ACCESSORIES
STANDARDS
3) UL 458 only for inverters with GFCI output socket
9
12/1200
24/1200
48/1200
1200 VA
1000 / 900 W
2200 W
230 VAC or 120 VAC +/- 3 % 50 Hz or 60 Hz +/- 0.1 %
9.2 - 17 / 18.4 - 34.0 / 36.8 - 62.0 VDC
9.3 / 18.6 / 37.2 VDC
10.9 / 21.8 / 43.6 VDC
14.0 / 28.0 / 56.0 VDC
92 / 94 / 94 %
8 / 9.5 / 10 W
1 / 1.7 / 2.7 W
Adjustable
a – f
-40 to +60 °C (fan assisted cooling)
(derate 1.25 % per °C above 40 °C)
max 95 %
Steel chassis and plastic cover (blue Ral 5012)
Screw terminals
35/25/25 mm² / AWG2/4/4
230 V: Schuko (CEE 7/4), IEC-320 (male plug included)
UK (BS 1363), AU/NZ (AS/NZS 3112)
120 V: Nema5-15R, NEMA GFCI (2x Nema5-15R with GFCI)
IP 21
7.7 kg/17 lbs
117x232x327
4.6x9.1x12.9
(12 V model: 117x232x367)
Yes
Filax or Multi
EN/IEC 60335-1 / EN/IEC 62109-1 / UL 458 (3)
EN 55014-1 / EN 55014-2
IEC 61000-6-1 / IEC 61000-6-3
ECE R10-4
EN 50498