Refer to the illustrations on page 2 of this manual.
1
voltage settings
2
current settings / button indicates
3
M1 to M4
4
memory key
5
output / cut-off key
5.
Operation
During the power-on status, the "Voltage Settings" shows the voltage value before the device powered off.
When the "Button Indicates" display shows "SET", the device is available for settings and output of device is
cut off.
Push the "up" or "down" buttons to adjust the preferred voltage value.
The maximum voltage value is 30 VDC, 60 VDC, 100 VDC.
When the "output" button is pushed, the device is under output state.
Push the "memory" button to enter save/recall status, the output is cut-off.
When the "Button Indicates" display shows "EP0", push "up" or "down" to save your preferred voltage
values.
When the "Button Indicates" display shows "EP0", push "M1", "M2", "M3", "M4" or "Memory" to save the
preferred voltage settings into the device memory. The "Button Indicates" display shows "E01", "E02",
"E03", "E04".
To recall the saved voltage values, just push "M1", "M2", "M3", "M4" or "Memory" and recall those voltage
values. The device is under output cut-off state.
The "Button Indicates" display shows the button status when "output" is off.
If the "output" button is pushed on, the "Button Indicates" display shows the current values of output.
The current shows the 3 decimal points in LED when the device is under current-limiting status.
6.

Cleaning and Maintenance

Disconnect the device from the mains prior to maintenance activities.
The power supply cables must not show any damage. Have a qualified technician maintain the device.
Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents.
There are no user-serviceable parts, apart from the fuse. Contact your dealer for spare parts if necessary.
Store the device in a dry, well-ventilated, dust-free room.
7.

Technical Specifications

input voltage
output voltage
output current
ripple voltage
dimensions
weight
fuse
working altitude
working temperature
relative humidity
Use this device with original accessories only. Velleman nv cannot be held responsible in the event
of damage or injury resulting from (incorrect) use of this device. For more info concerning this
product and the latest version of this manual, please visit our website www.velleman.eu. The
information in this manual is subject to change without prior notice.
© COPYRIGHT NOTICE
The copyright to this manual is owned by Velleman nv. All worldwide rights reserved. No part of this
manual may be copied, reproduced, translated or reduced to any electronic medium or otherwise without the
prior written consent of the copyright holder.
V. 04 – 30/06/2020
LABPS6030SM
6
voltage down regulation key
7
voltage up regulation key
8
power switch
9
output positive terminal
10
output negative terminal
230 V~, 50 Hz, 11 A, 2100 W, pf: 0,63
0-60 VDC adjustable max.
30 A max.
≤ 30 mVrms
275 × 360 × 145 mm
6.5 kg
automatic circuit-breaker C25
≤ 2000 m
18-28 °C
≤ 80 %
4