Start-Up And Use - ChefLine TAVOLO TN-BT Manuel D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 47
2.
It is advisable to install an onnipolar sectioning switch with opening of contacts at least 3 mm wide at the source
as for example automatic switch, fuse wire (the fuse screw must be removed from the socket) switch for fault
current and electricity meter.
3.
In order to save the appliance from overload or short circuit, the connection to the electricity has to be done
through a magneto-thermal switch high sensibility (30 mA) with manual re-establishment, of the right power.
4.
For protective device size, consider the power consumptions showed on the identifi cation label of the appliance
(APPENDIX 2 – identifi cation label product)
5.
It is necessary that the connection cable section is commensurate to the power consumption of the unit.
6.
The law requires that the unit is earthed; therefore it is necessary to connect it to an effi cient earth
connection. In order to prevent any risks if the electrical cable and the compressor supplied are da-
maged, these must be replaced by qualifi ed technician. Installation must be carried out only by quali-
fi ed technicians according to the regulation in force. No liability whatsoever can be accepted if the above in-
structions in not complied with.
WARNING
Any operation of ordinary and extraordinary maintenance of the appliance must be done disconnecting
the electric power supply. This maintenance must be done by qualifi ed technician.
The plug has to be always connected to a fi xed outlet. It is strictly forbidden to connect the appliance
plug to an extension cord or an adapter.
2.2 START UP AND USE
WARNING
Before to proceed to the switch-ON of the cabinet you have to verify as follow:
don't start the appliance with humid or wet hands
appliance surfaces and surrounding are dry
the cabinet with built-in unit had been placed in vertical position, if it should be sloped, we suggest to wait
at least 8 hours before to proceed with the start-up.
the parameters regulation are referring to the use instruction of the control panel attached to the present manual.
before connecting the plug in the socket check if the sectioning unit is in the
position marked by "0," "OFF"
for remote unit cabinet the fi rst starting has to be made by qualifi ed technicians.
After having checked as above, it is possible to start the appliance, giving electricity from the general power pack
(see paragraph. 2.1). Press green button in position n. 1, ON.
WARNING
Before loading the food on the appliances, wait that the temperature needed is the same on the con-
trol panel. Avoid to set a lower temperature than that suggested according to the category the cabinet
belong to in order to avoid evaporator block.
To regulate functioning parameters please follow the instruction attached to the present manual.