Version fi tted with built-in refrigeration unit:
• The Counters units models are fi tted with a drain hose and U-trap for connecting to the water drainage network (to
be carried by the client). See see the APPENDIX 3 - "VERSIONS".
The refrigerated table must never be installed without a U-trap, each drain must have a U-trap.
For more information please, see the APPENDIX 3 - "VERSION".

1.5 POSITIONING AND FEET REGULATION

1.6 INSTALLATION INSIDE YOUR SHOP/RESTAURANT /WORKROOM

It is advisable to install the refrigerated table inside an area with an air conditioning system. Please note that
malfunctions may arise in areas that are not provided with air conditioning, e.g. condensation formation
ATTENTION
In order to allow a good functioning of the Counter please draw attentions to the following instructions:
• Do not position the unit in an area directly exposed to sun light or to other heating sources,
such as high intensity incandescent lighting systems, ovens or other radiant heating sources, e.g. heating
radiators etc.
• Do not position the unit nearby door openings producing air currents, whether doors or win-
dows or directly exposed to air from fans, vents or fan coil unit air conditioner.
• Do not block or obstruct the air inlets of the built-in refrigeration unit.
• Do not place any objects on the unit, including boxes or any other type of objects; leave the entire
perimeter of the unit completely free so that air can circulate properly.
• Do not place the Refrigerated Counter inside areas with high relative humidity levels (it may
cause formation of condensation)
• Do not position the refrigerated table inside a closed niche, as there is not enough air circulation
and may cause the refrigeration unit to not work properly.
• Don not place the unit one above another.
• Verify that the room in which the Counter is placed must be suffi ciently aired, even when the
shop is closed.
Verify that in the installation room there is enough air turnover, even during closing and rest hours. In
this way the expansion/condensing unit will work correctly.

1.7 WALL MINIMUM DISTANCE

Refrigerated Counters | User and Maintenance Manual | EN
Place the Counter in a perfect horizontal position, acting if necessary on
the screw type adjustable feet. Use a spirit level to check it. The Counter
must be placed in order to operate properly and allow the correct defrost
condensate water draining. In this way you will avoid noisy vibrations of the
condensing unit. Check the correct positioning of the condensate water basin
and its draining.