Terminal Board
*1
Holder (Clamper)
Connecting Cable
Terminal screw
Tightening torque cN•m {kgf•cm}
M4
M5
*1 - Earth wire must be longer than other cables for safety reasons
WIRE STRIPPING AND CONNECTING REQUIREMENT
Wire stripping
Indoor/outdoor
connecting
terminal board
No loose strand
when insert
Conductor
Conductor
fully insert
over insert
ACCEPT
PROHIBITED
CONNECTING REQUIREMENT
For SDC03*3E5/SDC05*3E5
The equipment's Power Supply 1 complies with IEC/EN 61000-3-2.
The equipment's Power Supply 1 complies with IEC/EN 61000-3-3
and can be connected to current supply network.
The equipment's Power Supply 2 complies with IEC/EN 61000-3-2.
The equipment's Power Supply 2 complies with IEC/EN 61000-3-11
and shall be connected to suitable supply network, with the following
maximum permissible system impedance Z
interface. Please liaise with supply authority to ensure that the Power
Supply 2 is connected only to a supply of that impedance or less.
INSTALLATION OF REMOTE
7
CONTROLLER AS ROOM
THERMOSTAT
Remote Controller 3 mounted to the Indoor Unit can be moved to
the room and serve as Room Thermostat.
Installation Location
Install at the height of 1 to 1.5 m from the fl oor (Location where
average room temperature can be detected).
Install vertically against the wall.
Avoid the following locations for installation.
1. By the window, etc. exposed to direct sunlight or direct air.
2. In the shadow or backside of objects deviated from the room
airfl ow.
3. Location where condensation occurs (The Remote Controller
is not moisture proof or drip proof.)
4. Location near heat source.
5. Uneven surface.
Keep distance of 1 m or more from the TV, radio and PC. (Cause
of fuzzy image or noise)
RCCB/ELCB
*1
Power Supply Cord
157~196 {16~20}
196~245 {20~25)
5mm or
more
(gap between
wires)
Conductor not
fully insert
PROHIBITED
= 0.426 at the
max
Remote Controller Wiring
Indoor unit
Remote Controller wiring
(fi eld supply)
No polarity
Terminal for Remote Controller wiring
Remote Controller cable shall be (2 x min 0.3 mm²), of double
insulation PVC-sheathed or rubber sheathed cable. Total cable
length shall be 50 m or less.
Be careful not to connect cables to other terminals of Indoor Unit
(e.g. power source wiring terminal). Malfunction may occur.
Do not bundle together with the power source wiring or store in the
same metal tube. Operation error may occur.
Remove The Remote Controller From Indoor Unit
1. Remove the top case from the bottom case.
2. Remove the wiring between Remote controller and Indoor Unit
terminal. Remove the bottom case from the Control board cover
by loosening the screws. (3 pieces)
Claw
(2 places)
Disconnect the
Remote controller
wiring
Remote Controller
1
2
Insert the
driver and
slightly turn.
Flat-blade
screwdriver
Bottom
case
7