Télécharger Imprimer la page

WAGNER W 400 Manuel D'instructions page 31

Publicité

Les langues disponibles

Les langues disponibles

W 400
front part and gun rear part against each other and take them apart.
11) Screw of the container and empty it. Pull out the suction tub with container seal.
CAUTION!
Never clean seals, diaphragm and nozzle or air holes of the spray gun with metal
objects.
The ventilation hose and diaphragm are only solvent-resistant to a limited
extent. Do not immerse in solvent, only wipe.
12) Pull the ventilating hose (Fig. 10, 1) at the top from the gun body. Screw off the valve
cover (2). Remove the diaphragm (3). Clean all the parts carefully.
Never hold the spray gun rear part under water or immerse it into liquids.
Clean the housing only with a moistened cloth.
13) Clean the outside of the spray gun and container with a cloth soaked in solvent or
water.
14) Remove the adjustment ring (fig. 11, 1) carefully from the union nut (2).
15) Unscrew the union nut (fig. 11, 2) and remove the air cap (3), air screen (4), and nozzle
(5). Clean the air cap, air screen, nozzle seal (6) and nozzle with a brush and solvent
or water.
16) Assemble the parts again (see "Assembly").
Assembly
The unit may only be operated with an integer diaphragm (Fig. 10, 3).
Place the diaphragm (Fig. 10, 3) with the pin facing upwards on the bottom section of
the valve. Also see the marking on the gun body.
Place on the valve cover (Fig. 10, 2) and screw it closed.
Place the ventilating hose (Fig. 10, 1) on the valve cover and on the nipple at the gun
body.
Attention! Never operate the device if the nozzle seal is either damaged or
missing. If the nozzle seal is either missing or damaged liquids can enter
the device and increase the risk of an electric shock.
Push the nozzle seal (fig. 12, 6) over the needle (7); the groove (slot) should point towards
you.
Place the nozzle (fig. 12, 5) on to the gun body with the recess facing downwards.
Attention: Position of needle must be congruent with the nozzle aperture. (Fig.13)
Put the air screen (fig. 14, 4) in the air cap (3). Put both on the nozzle (5) and secure with
the union nut (2).
Adjust the setting ring (fig. 15, 1) so that the two "horns" grip the air cap and the red
adjustment lever rests on the pin.
Place the container seal from below on the suction tube and slide it over the collar, while
turning the container seal slightly.
Insert the suction tube with container seal in the gun body.
GB
25

Publicité

loading