WORMS ACCESS 3000 i Manuel D'utilisation page 37

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5.6. AC CURRENT
Before starting the generator, make sure that total power of loads (total of resistive, capacitive and
inductive loads) does not exceed rated power of the generator.
Determine your power need by finding the rated output of every device to be fed.
Find the rated output of every device. This information is given by the manufacturer's tool and is
on the manufacturer plate of your equipment. You can also find it in the user manual of your tool.
In general, capacitive and inductive loads, especially motor-driven devices have a big starting current
when starting. The following table is a reference for when connecting to the electric appliances.
EXAMPLES OF STARTING POWERS FOR TOOLS AND DEVICES
TOOL / DEVICE
Vacuum cleaner
Radiator
Electric boiler
Freezer
Oven microwaves
Hi-fi, TV, Computer, Printer
Incandescence light
Halogen light
Light low consumption. / fluorescent
Overload operation will greatly shorten generator service life. If the generator set is
connected to multiple loads or electric appliances, please first connect to one with
the highest starting power, then, the one with the second highest starting power, and
connect others one by one, each with a lower starting power than the preceding one,
finally, connect the one with the lowest starting power. (Fig. 06)
Example Absorbed
COEF.
Power Watts
2
900 W
1
1800 W
1
2000 W
3
400 W
2
800 W
1
600 W
1
100 W
1
500 W
2
100 W
EN
FR
Starting power
required in watts
ES
1800 W
IT
1800 W
RO
2000 W
1200 W
1600 W
600 W
100 W
500 W
200 W