Checking Burner Cap Placement
Check to make sure that there is no gap between the
burner parts. You may gently try to move the burner
parts from side to side to check if they are properly
placed.
Check the Installation
Check operation of electric igniters. Check flame
characteristics. Flame should be blue with no yellow tip.
Yellow Flames:
Further adjustment is required.
Yellow Tips on Outer Cones:
Normal for LPG Gas.
Soft Blue Flames:
Normal for Natural Gas.
If the flame is completely or mostly yellow, verify that the
regulator is set for the correct fuel. After adjustment,
retest.
Some yellow streaking is normal during the initial start-
up. Allow unit to operate 4-5 minutes and re-evaluate
before making adjustments.
Removing the appliance
Disconnect the appliance from the power and the gas
supply. Push out the appliance from below.
9
CAUTION
Risk of damage! Do not lever out the appliance
from above.
10
Conversion to another type of gas
This gas stovetop corresponds to the categories
specified on the rating plate. By changing nozzles, it is
possible to convert the appliance to any of the gases
listed on the plate. The conversion kit is included in the
scope of delivery.
Only a licensed specialist is authorized to switch the
appliance to another gas type.
Before carrying out the conversion, turn off the
electricity and gas supply.
B) Changing the low burn nozzle:
1
Remove the cover from the underside of the
appliance under the gas valves. The low burn nozzle
is located in the gas valve and is screwed in from
below.
2
Unscrew the nozzle and insert the new nozzle as
specified in the low-setting nozzle table. The nozzle
must be screwed in fully.
3
Fit the cover cap again.
A) Changing the full burn nozzle:
1
Remove the pan supports and burner lids.
2
Change the nozzles. A suitable spanner can be
obtained via our after-sales service (ordering code
00424699). Care should be taken to ensure that the
nozzles do not break off when screwed in or out.