The universal transmitter periodically samples signals from thermo-
couples, resistance thermometers, strain gages, resistive sensors, etc.
These signals are converted into output signals proportional to the
measured values.
The output signal can be a voltage or a current.
3-port isolation with Safe Isolation up to 300 V AC/DC according to
EN 61140 ensures optimum protection of personnel and equipment
as well as unaltered transmission of measuring signals.
3-port isolation of inputs, outputs and power supply
Inputs
Power supply
Basic insulation
Working voltage
Overvoltage category
Pollution degree
Safe Isolation according to EN 61140
by reinforced insulation according to EN 61010-1
Working voltage
Overvoltage category
Pollution degree
Outputs
up to 300 V AC/DC
II
2
up to 300 V AC/DC
II
2
Function
Warning!
For applications with
high working voltages,
ensure there is suffi-
cient spacing or isola-
tion from neighboring
devices and protection
against electric shocks.