Télécharger Imprimer la page

Atlantic PC Notice D'instruction page 10

Publicité

3. HYDRAULIC CONNECTION
- It is necessary to clean the supply piping prior to the hydraulic connection. The connection to the hot water outlet is to be
carried out with a cast iron or steel sleeve or a dielectric connector, to avoid corrosion of the pipe (direct contact iron /
copper). The use of brass fittings is prohibited.
3.1 INSTALLATION PRESSURISED: See fig. ❼,❽, ❾&❿, p.4. Always install a new safety device on the cold water
pipe of the water heater, which comply with the standards (EN 1487 in Europe), with a pressure of 7 or 9 bars (0.7 or
0.9 MPa) according to the nominal pressure, with diameter 1/2" or 3/4" (Table p.1).
3.2 INSTALLATION UNPRESSURISED: See fig.⓫&⓬, p.4. For the supply of a single point of use, the installation must
be carried out with an optional special mixer tap.
- CAUTION: During heating up, water dripping may occur at the valve, do not obstruct the dripping. The safety device if
supplied does not meet the criteria for installation on French territory (Mainland and Overseas territories), do not use it.
4. ELECTRICAL CONNECTION
- Refer to the corresponding diagrams p.2 & 5 (See fig. ⓭, ⓮, ⓯, ⓰, ⓱&⓲).
- The water heater can be connected and operated only on AC 230V. Connect the heater with a rigid cable with conductors
2,5mm ². Use a standardised channeling (rigid or flexible conduit) until the calibrated housing cover.
- Directly connect devices with a cable or plug. In France, a product with plug is strictly prohibited and cannot be sold and
installed.
- Always connect the earth conductor of the cable to the earth ground wire or connect the earth conductor to the appropriate
terminal identified by the symbol
be longer than those of phases. The installation must be equipped, upstream of the appliance, with a bipolar cut-out device
(minimum contact distance of 3 mm fuse, breaker switch). In the case where HYDRAULIC connexions are in insulated
material, electrical circuits shall be protected by a differential circuit breaker 30 mA adapted to local standards.
- Thermal circuit breaker: All products are equipped with a thermostat including a thermal circuit breaker with manual reset,
which cuts the power in case of overheating. In case the security trips A: Cut the power before any operation. B: remove
the plastic cover. C: Check the electrical connection. D: Reset security. In case of repetitive tripping, replace the
thermostat. Never bypass safety or regulation thermostat. Connect the power only on the sockets or thermostat input.
5. STARTING UP
- CAUTION! NEVER POWER THE WATER HEATER WITHOUT WATER: Models with an electric heating element will be
certainly damaged.
- Fill the tank completely. Before powering up, open the hot water taps, drain the pipes in order to empty the air.
- Check the tightness of the tubes and of the flange seal under the plastic cover. In case of leaking tighten moderately.
Check the operating of the hydraulic components and of the safety valve.
- Turn the power on. After 15 to 30 minutes, depending of the capacity of the device, the water should drip from the drain.
This is normal and due to the expansion of water. Check connection leaks and seal. During heating and according to the
water quality, hot water tanks can make a bubbling noise. This noise is normal and does not indicate any defect of the unit.
The thermostat is factory set to stop at 65 ± 5 ° C. IMPORTANT: If you see a continuous release of steam or hot water
from the drain or when opening a faucet, turn off immediately the power to the water heater and call a professional.
6. MAINTENANCE
- CAUTION: Before removing the plastic cover, make sure the power is turned off to avoid any risk of injury or electric shock.
The domestic maintenance must be done by the user. Operate the safety device every month to prevent scaling and
check that it's not blocked. Not executing this maintenance may cause damage and the loss of the warranty. Maintenance
by qualified personnel A: Scaling: Remove the scale deposited as mud. Do not scratch or hit the scale sticking to the
walls to avoid damage to the coating. Do not forget to change the seal and reassemble the appliance, check that there is
no leakage of water after the first heating. B: For devices with magnesium anode, change the magnesium anode every two
years or as soon as its diameter is less than 10mm. C: The change of a sheathed heating element involves draining of the
water heater and the change of the seal. Reassemble the heating element, reasonably tight nuts (cross tightening), check
that there is no leakage after the first heating-up, tighten again if necessary. D: Drain: Turn off power and cold water
supply, Open hot water taps and drain valve of the safety device. For under sink water heater, disconnect the hydraulic
tubes and return for emptying.
- IMPORTANT: The replaceable parts are: thermostat, gasket, heater, magnesium anode, cable, cover, light, switch.
Warranty is subject to the use of original spare parts from manufacturer. ADVICE TO THE USER: In case of hard
water with TH> 20 ° f ( >200 ppm ), we recommended to soften the water. If a water softener is used, the remaining water
hardness should be more than 15 ° f. In the case of a longer absence and especially in winter, drain your device, then
follow the procedures for starting-up.
7. WARRANTY (EN)
- The water heater must be installed, operated and maintained in accordance with the state of the art and with the standards
in force in the country of installation and the instructions in this manual. In the European Union this unit has the legal
guarantee granted to consumers under Directive 1999/44/EC, this warranty is effective from the date of delivery of the
goods to the consumer.
replacement of the tank and components recognized as defective, excluding replacement and transport cost.
the table below.
This warranty does not affect any rights you may benefit as a result of the application of the statutory
warranty. It applies in the country of purchase of the product, provided it is also installed on the same territory. Any damage
must be reported to the depositary before exchange under warranty, and the unit will remain available to insurance experts
and the manufacturer.
Legal guarantee
Additional commercial warranty
on tanks and heating element enamel
. This connection is compulsory for safety reasons. The earth wire green - yellow must
In addition to the legal guarantee, some products have an extended warranty, limited to the free
PC/E-SERIES/EGO
2 years
+1 year
OPRO/OPRO+/CERAMIC/STEATITE
2 years
5 years
Refer to

Publicité

loading

Ce manuel est également adapté pour:

N3cN4D400Gv