For the Fitter
Button
LCD
INST
M
for approx.
3 sec.
SOND
M
E1
P
- 14
E2
P
P
LSO
E3
P
TEP
P
TSP
P
P
P
UZ
26
All manuals and user guides at all-guides.com
Button
VR LF LZ KU
P
ED
SH
SYN
VR LF LZ KU
ED
SH
SYN
+
VR LF LZ KU
or
ED
SH
° C
SYN
+
VR LF LZ KU
or
ED
18
SH
° C
SYN
+
VR LF LZ KU
or
ED
15
%
SH
SYN
+
VR LF LZ KU
or
ED
SH
SYN
+
VR LF LZ KU
or
ED
20
%
SH
SYN
+
VR LF LZ KU
or
ED
85
%
SH
SYN
+
VR LF LZ KU
or
ED
0
%
SH
SYN
+
VR LF LZ KU
or
ED
SH
SYN
Note
INSTallation menu – After this menu is activated, the
parameters „EDS" and „WF" must be set as described under
„Basic settings" on page 23. The parameter „LM" can remain set
to the displayed value. (Press the M button after entering the
value)
SOND (special settings)
Full charging – Outside temperature (calculated using the
following formula) at which the storage heater is to be fully
charged. Setting range: -25 to 11 °C
t
E1 = ϑ R – –––––––––––– ( ϑ R – ϑ a)
F
t
+ t
F
ZF
ϑR=Nominal room temperature
ϑa= Normal outside temperature to DIN 4701
t
= Release length
F
t
= Additional-release length
ZF
Charging start – Outside temperature at which charging of the
storage heater is to begin (value must be at least 6 °C above the
E1 value).
Factory setting 18 °C
Summer logic – If E2 is underranged, the storage heater is
charged to at least this value.
Setting range: 0 to 30 %
Reduction time – Depends on the control type. Setting range: 0
to 12 h
Forward control
E3 = 0
Spread control
E3 = Main release hours / 2
Backward control
E3 = Main release hours - 1 h
Charge minimum – End point of day-time characteristic in %
of the day-time start value, corresponds to the remaining
charge that the storage heater has at the end of the day-time
characteristic.
Setting range: 0 to 60 %
Day-time start value in % of the nominal charging level.
This can be used to reduce day-time recharging.
Setting range: 0 to 100 %
Charge reduction in % of the nominal charging level with
activation of terminal KU, e.g. for holiday mode: reduced
charging during absence.
Setting range: 0 to 100 %
Cycle time of timing element – usually 22h. Depends on
charging model of power supply company.
(e.g. 8h/2 = 4h)
(e.g. 8h-1 = 7h)