Maintenance and service
7.1
Safety during cleaning
Take note of the specifications in the safety data sheet, the general occupational health and
safety rules and the HEROSE information sheet "Use with oxygen" if degreasers are used for
process-related reasons for the cleaning of bearing parts, unions and other precision parts.
7.2
Maintenance
The maintenance and inspection intervals must be defined by the operating company according to the
operating conditions and the national regulations.
The manufacturer's general recommendations for the maintenance and inspection of the globe valves are
given in the table below and are based on the national standards of the country of manufacture.
Inspection and maintenance intervals
Inspection
Inspection
Functional testing
External inspection
Internal inspection
Strength test
22
Operating instructions
Recommended intervals
Interval
During start-up
Annually
Every 2 years
Every 5 years or ≥ 500 loading
cycles
Every 10 years
Phone +49 4531 509-0
Scope
Visual inspection
of the valve for damage;
of the valving marking for
legibility;
for absence of damage to
the sealing.
Leak-tightness
Union of the valve seat.
If existent, actuation of the lifting
device.
If present, test of lifting device
including visual inspection.
Function and tightness test
including visual inspection.
Replacement of all sealing
elements by the manufacturer
including functional, tightness
test and visual inspection.
Replacement of all sealing
elements by the manufacturer
including functional, leak-
tightness, pressure test and
inspection.

Publicité