Fault
The pump does not start
or stops during opera-
tion
The pump capacity drops
or is too low
Quick-Connect cannot
be opened
Technical data
Device performance data
Mains voltage
V
Power frequen-
Hz
cy
Nominal power W
Maximum flow
l/h
rate
3
Solids content in
kg/m
water
Pressure (max.) MPa
(bar)
Delivery height
m
(max.)
Immersion
m
depth (max.)
Perm. temp.
°C
feed fluid
Particle size
mm
(max.) of per-
missible feed
fluids
Minimum fluid
mm
level (manual
mode)
Residual fluid
mm
height
12
Cause
The power supply is disconnected.
The thermal protection switch has
switched off the pump because of over-
heating.
Dirt particles are trapped in the suction
area.
The float switch switches the pump off.
The suction area is clogged.
The delivery rate of the pump depends
on the delivery head and the connected
periphery.
The cross-section on the pressure side is
narrowed, e.g. due to the valve/ball tap
not being fully open.
The pressure side hose is kinked.
The Quick-Connect plug system is
blocked by contamination.
SP
SP
SP
9.000
9.500
11.000
Flat
Dirt
Dirt
230-240 230-240 230-240
50
50
50
280
280
400
9.000
9.500
11.000
>2,5
>2,5
>2,5
0,06
0,06
0,07
(0,6)
(0,6)
(0,7)
6
6
7
7
7
7
5...35
5...35
5...35
5
20
20
7
60
60
1
25
25
Rectification
1. Check the fuses and the electrical connec-
tions.
1. Pull the mains plug out of the socket.
2. Allow the pump to cool down.
3. Clean the suction area.
4. Prevent the pump from running dry.
1. Pull the mains plug out of the socket.
2. Clean the suction area.
1. Automatic mode: Check the position and
free movement of the float switch and cor-
rect if necessary, see chapter Automatic
mode.
2. Manual operation: Attach the float switch
correctly, see chapter Manual operation.
1. Pull the mains plug out of the mains socket
and clean the suction area.
1. Observe the maximum delivery height, see
chapter Technical data. If necessary, se-
lect a larger hose diameter or shorter hose
length.
1. Fully open the valve / ball tap.
1. Eliminate the kink points in the hose.
1. Remove the clip and clean it.
Weight (without
accessories)
Subject to technical modifications.
Optimising the flow rate
The flow rate is further increased:
● The lower the delivery height is.
● The greater the diameter of the hose used is.
● The shorter the hose used is.
● The smaller the pressure loss caused by the con-
nected up accessories.
Declaration of Conformity
EU Declaration of Conformity
We hereby declare that the machine described below
complies with the relevant basic safety and health re-
English
SP
SP
9.000
9.500
Flat
Dirt
kg
3,7
3,8
SP
11.000
Dirt
4,4

Publicité