Optics
Fibroptonic
Ref : 202 012
1 Purpose
To approximately determine the concentration of a coloured solution from a standard
solution of known concentration.
2 Experiment no. 24
ENGLISH
FIBROPTONIC
2.1 Equipment:
Photoresistor module
Ohmmeter
Directive source of white light or laser
Set of identical glass tanks
Different solutions of potassium permanganate of concentrations between 10^-4
and 10^-1 mol/litre.
2.2 Set-up and experiment:
Connect the ohmmeter to the black and yellow terminals of the photoresistor.
Illuminate the photoresistor with the light beam
Place a glass tank filled with a decimolar potassium permanganate solution
(control solution) in the beam; measure the resistance R of the photoresistor
(figure 28).
Restart the operation with the other control solutions of up to 10^-4 mol/l. Each
time, check that the tank is perpendicular to the beam (for this, observe the
laser's reflected spot) and that the distance from the source to the photoresistor
is unchanged.
Plot the curve of the resistance R in function of the concentration C.
Pour the solution whose concentration needs to be determined into the glass
tank, measure R, deduce C from the curve established earlier.
Laser
Figure 28: Determining the concentration of a coloured solution by absorption.
COLORIMETRY
Tank tilled wih a
colored solution
70
SHEET
12
Ohmmeter
Photoresistor