Cleaning of the Spray Gun

• Prior to cleaning, please disconnect the paint spray gun from the
compressed air circuit!
• Risk of injury due to unexpected leakage of compressed air or mate-
rial!
• Empty paint spray gun and gravity flow cup completely, dispose of
paint material appropriately!
• Disassemble and install components very carefully! Exclusively use
included special tools!
• Use neutral cleaning solution (pH value 6 to 8)!*
• Do not use acids, alkalines, bases, pickling agents, unsuit-
able regenerates or other aggressive cleaning solutions!*
• Do not soak paint spray gun in cleaning solution!*
• Drillings should be cleaned with SATA cleaning brushes or SATA nozzle
cleaning needles only. The use of other tools may cause damage or
may affect the spray pattern. Recommended accessory: cleaning kit
Art. No. 64030.
• Exclusively use spray gun washing machines recommended by SATA!
Please observe the operating instructions!
• The air passages have to be put under pressure with clean compressed
air during the entire cleaning process!
• Nozzle head has to point downwards!
• Remove the spray gun from the gun washing machine imme-
diately after the cleaning process!*
• Never use ultrasonic cleaning devices - leads to damage of
nozzle set and gun surface!
• After cleaning, the spray gun, the material passages, the air
cap including thread as well as the gravity flow cup have to
be blown dry with clean compressed air!*
* otherwise risk of corrosion