Electrical Connections; Important Safety Instructions; Electrical Requirements - LG LCE3010SB Manuel Du Propriétaire

Masquer les pouces Voir aussi pour LCE3010SB:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

I N S TA L L AT I O N I N S T RU C T I O N S

ELECTRICAL CONNECTIONS

IMPORTANT SAFETY INSTRUCTIONS

• Be sure your cooktop is installed and grounded
properly by a qualified installer or service
technician.
• This cooktop must be electrically grounded in
accordance with local codes or, in their
absence, with the National Electrical Code
ANSI/NFPA No. 70, latest edition in the United
States.
WARNING
The electrical power to the cooktop must
be shut off while line connections are
being made. Failure to do so could result
in serious injury or death.

ELECTRICAL REQUIREMENTS

Observe all governing codes and local
ordinances.
1
A 3-wire or 4-wire single-phase 120/240 or
120/208 volt, 60 Hz AC-only electrical supply
is required on a separate circuit fused on
both sides of the line (time-delay fuse or
circuit breaker is recommended). DO NOT
fuse neutral. The fuse size must not exceed
the circuit rating of the appliance specified
on the nameplate.
36" Radiant cooktop can consume up to
2
9200W at 240 VAC. A 50 Amp circuit breaker
with wire guage #8 AWG must be used.
30" Radiant cooktop can consume up to
7700 W at 240 VAC. A 40 Amp circuit
breaker with wire guage #8 AWG must be
used.
NOTE: Wire sizes and connections must
conform with the fuse size and rating of the
appliance in accordance with the National
Electrical Code ANSI/NFPA No. 70, latest
edition, and local codes and ordinances.
WARNING
An extension cord must not be used with
this appliance. Such use may result in a
fire, electrical shock, or other personal
injury.
24
PROVIDING THE ELECTRICAL
CONNECTION
Install the junction box under the cabinet and run
120/240 or 120/208 volt, AC wire from the main
circuit panel.
NOTE: DO NOT connect the wire to the circuit
panel at this time.
3
The appliance should be connected to the
fused disconnect (or circuit breaker) box
through flexible armored or nonmetallic
sheathed cable. The flexible armored cable
extending from this appliance should be
connected directly to the grounded junction
box. The junction box should be located as
shown on page 21 or 23 with as much slack
as possible remaining in the cable between
the box and the appliance, so it can be
moved if servicing is ever necessary.
4
A suitable strain relief must be provided to
attach the flexible armored cable to the
junction box.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Lce3610sb

Table des Matières