12 Device Information

1
Type and order code
2
Design
2.1
Model
2.2
Controller
2.3
Thermal energy metering
2.4
Installation location / degree of protection according to EN 60 529
2.5
Performance levels
2.6
Frost protection condensate tray / heating water
3

Operating limits

3.1
Heating water flow / return
3.2
Cooling water flow
3.3
Air (heating)
3.4
Air (cooling)
4
Performance data / flow rate
4.1
Heating water flow rate / internal pressure differential
Maximum
Minimum
3
4.2
Heat output / COP
4.3
Cooling water flow rate / internal pressure differential
4.4
Cooling capacity / COP
4.5
Sound power level of device / outdoors according to EN 12102dB(A)
4.6
Sound pressure level at a distance of 1m
4.7
Air flow with an external pressure differential of
5
Dimensions, connections and weight
5.1
Device dimensions without connections
5.2
Device connections for heating system
5.3
Device connections to additional heat exchanger (waste heat recovery) Inch
5.4
Weight of the transportable unit(s) incl. packaging
5.5
Refrigerant; total filling weight
5.6
Lubricant; total filling quantity
6
Electrical connection
6.1
Supply voltage / fuse protection
6.2
Control voltage / fuse protection
6.3
Starting current with soft starter
6.4
Nominal power consumption at A2 / W35 / max. power consumption
6.5
Nominal current at A2 / W35 / cosϕ
6.6
Power consumption of compressor protection (per compressor) W
7
Complies with the European safety regulations
8
Additional model features
8.1
Type of defrosting
1. The heat circulating pump and the heat pump controller must always be ready for operation.
2. These data indicate the size and capacity of the system according to EN 14511. For an analysis of the economic and energy efficiency of the system, the bivalence point and
regulation should be taken into consideration. These specifications can only be achieved with clean heat exchangers. Information on the maintenance, start-up and operation can
be found in the respective sections of the installation and operating instructions. The specified values have the following meaning, e.g. A7 / W35: Heat source temperature 7 °C
and heating water flow temperature 35 °C.
3. At maximum heating water flow rate
4. The specified sound pressure level corresponds to the operating noise of the heat pump in heating operation with a flow temperature of 35°C. The specified sound pressure level
represents the free sound area level. The measured value can deviate by up to 16 dB(A), depending on the installation location.
5. Please note that additional space is required for pipe connections, operation and maintenance.
6. See CE declaration of conformity
www.dimplex.de
1
°C
°C
°C
°C
2
A7 / W55/30
m³/h / Pa
m³/h / Pa
at A-7 / W45
kW / ---
at A2 / W35
kW / ---
at A7 / W35
kW / ---
at A7 / W45
kW / ---
at A10 / W35
kW / ---
A35 / W12/7
m³/h / Pa
at A27 / W7
kW / ---
at A27 / W18
kW / ---
at A35 / W7
kW / ---
at A35 / W18
kW / ---
4
dB(A)
m³/h / Pa
5
H x W x L cm
Inch
kg
type / kg
type / litres
A
2
kW
A / ---
LI 11TER+
Reversible
Internal
-
Indoors / IP 21
1
Heated / yes
up to 58 ± 2 / from 18
+7 to +20
-25 to +35
+15 to +40
1.9 / 10900
1.0 / 3000
EN 14511
6.6 / 2.7
8.8 / 3.1
11.3 / 3.6
9.6 / 3.1
12.1 / 3.9
1.3 / 5900
8.8 / 2.8
10.8 / 3.2
7.5 / 2.1
9.5 / 2.5
55 / 61
50
4200 / 0
1360 x 750 x 880
1 1/4 " external thread
1 1/4 " external thread
222
R404A / 5.1
Polyolester (POE) / 1.5
3~/PE 400 V (50Hz) / C16A
1~ / N / PE 230 V (50Hz) / C13A
23
2.86 / 3.9
5.16 / 0.8
70
6
Reverse circulation
12
LI 16TER+
Reversible
Internal
-
Indoors / IP 21
1
Heated / yes
up to 58 ± 2 / from 18
+7 to +20
-25 to +35
+15 to +40
2.6 / 14600
1.4 / 4500
EN 14511
10.5 / 2.9
9.9 / 2.5
14.9 / 3.6
14.7 / 3.3
16.6 / 3.9
1.8 / 7000
12.5 / 2.6
16.4 / 2.8
10.6 / 2.0
14.3 / 2.2
57 / 62
52
5200 / 0
1570 x 750 x 880
1 1/4 " external thread
1 1/4 " external thread
260
R404A / 5.7
Polyolester (POE) / 1.9
3~ / PE 400 V (50Hz) / C20A
1~ / N / PE 230 V (50Hz) / C13A
25
4.0 / 6.6
7.2 / 0.8
70
6
Reverse circulation
EN-11