• When battery pack is not in use, keep it away
from other metal objects, like paper clips, coins,
keys, nails, screws or other small metal objects,
that can make a connection from one terminal
to another. Shorting the battery terminals together
may cause burns or a fire.
• Under abusive conditions, liquid may be ejected
from the battery; avoid contact. If contact acci-
dentally occurs, flush with water. If liquid con-
tacts eyes, additionally seek medical help. Liquid
ejected from the battery may cause irritation or burns.
• Do not use a battery pack or tool that is dam-
aged or modified. Damaged or modified batteries
may exhibit unpredictable behavior resulting in fire,
explosion or risk of injury.
• Do not expose a battery pack or tool to fire or
excessive temperature. Exposure to fire or tem-
perature above 265°F (130°C) may cause explosion.
• Follow all charging instructions and do not
charge the battery pack or tool outside the
temperature range specified in the instructions.
Charging improperly or at temperatures outside
the specified range may damage the battery and
increase the risk of fire.
SERVICE
• Have your power tool serviced by a qualified
repair person using only identical replacement
parts. This will ensure that the safety of the power
tool is maintained.
• Never service damaged battery packs. Service
of battery packs should only be performed by the
manufacturer or authorized service providers.
SPECIFIC SAFETY RULES FOR
UTILITY CRIMPER
• Use tool only as directed. Only trained personnel
should operate tool.
To reduce the risk of arc flash,
WARNING
electric shock and property
damage, work on deenergized lines when
possible. Tool is not insulated. Should work
on energized lines be required, ensure all proper
precautions, including those contained in NFPA
70E, have been taken first.
• Do not use tool without crimping jaws installed.
Fingers could be crushed.
• Keep hands away from crimping jaws while tool
is in use. Fingers could be crushed.
•To reduce the risk of injury, wear safety goggles
or glasses with side shields when operating or
servicing the tool.
• Inspect and discard workpieces with cracks or
wear before use. Materials may crack or shatter.
• Use tool only with MILWAUKEE crimping jaws,
dies, and connectors for which they are rated.
Jaws, dies, and connectors must be used in an
APPROVED COMBINATION to achieve a suc-
cessful operation. Improper combinations can
result in a faulty crimp. Electric shock, fire, explosion,
and property damage could occur.
• Follow connector manufacturers' installation
instructions. Other uses may cause damage to
the tool, accessories, and workpiece.
• Chemical Burn Hazard. Keep coin cell battery
away from children.
• For best results, use only with energy absorbing
lanyards. Ropes, straps or chains may break
and cause failure. Do not use with lanyards at
full tension.
• Always use common sense and be cautious when
using tools. It is not possible to anticipate every
situation that could result in a dangerous outcome.
Do not use this tool if you do not understand these
operating instructions or you feel the work is beyond
your capability; contact Milwaukee Tool or a trained
professional for additional information or training.
• Maintain labels and nameplates. These carry
important information. If unreadable or missing,
contact a MILWAUKEE service facility for a free
replacement.
Some dust created by power sanding,
WARNING
sawing, grinding, drilling, and other
construction activities contains chemicals known to
cause cancer, birth defects or other reproductive
harm. Some examples of these chemicals are:
• lead from lead-based paint
• crystalline silica from bricks and cement and other
masonry products, and
• arsenic and chromium from chemically-treated
lumber.
Your risk from these exposures varies, depending
on how often you do this type of work. To reduce
your exposure to these chemicals: work in a well
ventilated area, and work with approved safety
equipment, such as those dust masks that are spe-
cially designed to filter out microscopic particles.
SYMBOLOGY
Volts
Direct Current
WARNING
property damage, work on deenergized
lines when possible. Tool is not insulated.
Should work on energized lines be re-
quired, ensure all proper precautions, in-
cluding those contained in NFPA 70E,
have been taken first.
WARNING
in use. Fingers could be crushed.
To reduce the risk of injury, wear safety
goggles or glasses with side shields when
operating or servicing the tool.
Read operator's manual
UL Listing for Canada and U.S.
C
US
SPECIFICATIONS
Cat. No. ..................................................... 2678-20
Volts .............................................................. 18 DC
Battery Charger ............................................M18™
Charger Type ................................................M18™
Module/FCC ID ........BGM220S2/QOQ-BGM220S2
Operating Temp ..................................... 0° - 122° F
High Voltage Field Rating ........................... 34.5 kV
Force ............................................................ 6 Tons